User Guide

150 Spheras Storage Director Installation and User Guide
132 Name MLXEV_SYSDEV_CHECK_SYSDEV_FAILED
Description Consistency check on logical drive failed.
Cause A logical device became critical.
A logical device failed.
Action See request sense data for more information.
Address ctl: 0 logdrv: 15
Severity 2 (Error)
Source ExPro InPro
133 Name MLXEV_SYSDEV_CHECK_PHYSDEV_FAILED
Description Consistency check failed due to physical disk failure.
Cause A physical disk failed.
Action See request sense data for more information.
Address ctl: 0 logdrv: 15
Severity 2 (Error)
Source ExPro InPro
134 Name MLXEV_SYSDEV_OFFLINE
Description Logical drive has been made offline.
Cause One/multiple physical disk(s) failed.
Action It may not be possible to recover from this error.
Contact your service representative.
Address ctl: 0 logdrv: 15
Severity 1 (Serious)
Source ExPro InPro
135 Name MLXEV_SYSDEV_CRITICAL
Description Logical drive is critical.
Cause One physical device failed.
Action Replace the physical device.
Start the rebuild, if required.
Address ctl: 0 logdrv: 15
Severity 2 (Error)
Source ExPro InPro
136 Name MLXEV_SYSDEV_CRITICAL
Description Logical drive has been placed online.
Cause Rebuild completed.
User set the physical disk online.
New configuration was added.
Action None
Address ctl: 0 logdrv: 15
Severity 4 (Information)
Source ExPro InPro
137 Name MLXEV_SYSDEV_AUTO_REBUILD_START
Description An automatic rebuild has started on logical drive.
Cause A physical disk failed and a spare device was available.
A spare physical disk was found and replaced the failed disk.
Action None
Address ctl: 0 logdrv: 15
Severity 4 (Information)
Source InPro
138 Name MLXEV_SYSDEV_MANUAL_REBUILD_START
Description A manual rebuild has started on logical drive.
Cause Client started the rebuild on user's request.
User replaced the failed device and 'raidbld' started the rebuild.
Action None
Address ctl: 0 logdrv: 15
Severity 4 (Information)
Source InPro
Table 2 RAID Controller Event Codes