102 Name MLXEV_SYSDEV_PFA_STOP
Description Finished predicted failure analysis on every physical disk.
Cause Controller finished predicted failure analysis on the physical disks.
Action None
Address ctl: 0
Severity 4 (Information)
Source ExPro
103 Name MLXEV_SYSDEV_BKGND_PATROL_START
Description Background patrol started or was resumed.
Cause Background patrol started.
Action None
Address ctl: 0
Severity 4 (Information)
Source ExPro
104 Name MLXEV_SYSDEV_BKGND_PATROL_STOP
Description Background patrol has found no more physical disks or was
commanded to stop.
Cause Background patrol finished or was stopped.
Action None
Address ctl: 0
Severity 4 (Information)
Source ExPro
128 Name MLXEV_SYSDEV_CHECK_START
Description Consistency check has started.
Cause User started a consistency check.
'raidbld' started a consistency check.
Action None
Address ctl: 0 logdrv: 15
Severity 4 (Information)
Source ExPro InPro
129 Name MLXEV_SYSDEV_CHECK_DONE
Description Consistency check has finished.
Cause Consistency check completed successfully without detecting any errors.
Action None
Address ctl: 0 logdrv: 15
Severity 4 (Information)
Source ExPro InPro
130 Name MLXEV_SYSDEV_CHECK_CANCELED
Description Consistency check is cancelled.
Cause User cancelled the consistency check.
Action Restart consistency check, if required.
Address ctl: 0 logdrv: 15
Severity 2 (Error)
Source ExPro InPro
131 Name MLXEV_SYSDEV_CHECK_ERROR
Description Consistency check on logical drive error.
Cause Inconsistent data were found.
Bad sectors were found.
A physical disk reliability problem.
Action See bad block and request sense table for more information.
Address ctl: 0 logdrv: 15
Severity 2 (Error)
Source ExPro InPro
Table 2 RAID Controller Event Codes