91 Name MLXEV_PPILOT_PRIMARY_DISK_NOT_FOUND
Description A primary logical drive was not found during initialization.
Cause PATHPilot reported a primary logical drive was lost during power
cycle.
Action Investigate possible causes such as cabling, controller failure, or HBA
failure.
Address PATHpilot: Last HBTL: 12,13,14,15
Severity 3 (Warning)
Source PATHpilot
92 Name MLXEV_PPILOT_NO_PATH_FOR_LD_FOUND
Description No paths were found for a logical drive during initialization.
Cause PathPilot reported all paths were lost to a logical drive during power
cycle.
Action Investigate possible causes such as cabling, controller failure, or HBA
failure.
Address PATHpilot: Last HBTL: 12,13,14,15
Severity 3 (Warning)
Source PATHpilot
93 Name MLXEV_PPILOT_RECOVERY_ON_STANDBY_PATH
Description A standby path has been recovered.
Cause PathPilot reported recovery of a standby path.
Action None. This indicates that storage access has been restored.
Address PATHpilot: Curr HBTL: 12,13,14,15
Severity 4 (Information)
Source PATHpilot
94 Name MLXEV_PPILOT_PATH_FAILURE_ON_STANDBY_PATH
Description A standby path failed.
Cause PathPilot reported a failure on a standby path.
Action Investigate possible causes such as cabling, controller failure, or HBA
failure.
Address PATHpilot: Curr HBTL: 12,13,14,15
Severity 3 (Warning)
Source PATHpilot
95 Name MLXEV_REPLACED_PHYSDEV_SMALLER
Description User replaced a configured physical disk with a disk of smaller
capacity.
Cause The new physical disk may have a smaller physical capacity than the
physical disk it replaced.
The controller's coercion setting may have reduced the configurable
size of the new physical disk.
Action None.
Address ctl: 0 chn: 13 tgt: 14
Severity 4 (Information)
Source InPro
96 Name MLXEV_FIBREDEV_LOOPID_SOFTADDR_OCCURRED
Description Device loop ID conflict (soft addressing) detected.
Cause Device loop ID conflict detected on a disk channel resulted in soft
addressing; potential data corruption.
Action Change index selector to enable hard addressing per enclosure
manufacturers specification.
Address ctl: 0 chn: 13
Severity 1 (Serious)
Source ExPro
Table 2 RAID Controller Event Codes