User Guide
146 Spheras Storage Director Installation and User Guide
86 Name MLXEV_CFG_COD_GROUP_NOT_INSTALLED_LDD_
USED
Description Configuration group not installed due to logical drive conflict.
Cause Logical drive already configured in another group.
Unable to install all the logical drives in the group.
Action Move to another controller.
Remove one or more existing configuration groups and reboot with this
group.
Address None.
Severity 4 (Information)
Source ExPro
87 Name MLXEV_CFG_COD_GROUP_NOT_INSTALLED_SAN_MAP_CO
NFLICT
Description Configuration group not installed due to SAN map conflict.
Cause SAN map conflicted with that of another installed group.
Action Move to another controller.
Remove one or more existing configuration groups and reboot with this
group.
Address None.
Severity 4 (Information)
Source ExPro
88 Name MLXEV_CFG_COD_GROUP_NOT_INSTALLED_FOREIGN
Description Foreign configuration group not installed.
Cause Foreign COD group found but not installed.
Action Move to another controller
Remove native configuration group and reboot with foreign group.
Address None.
Severity 4 (Information)
Source ExPro
89 Name MLXEV_CFG_COD_GROUP_NOT_INSTALLED_ALL_BAD_FOR
EIGN
Description No configuration group installed.
Cause All configuration groups are foreign and clash.
Controllers may have changed.
Action Move to another controller
Re-insert original controllers or remove some groups and reboot with
one group.
Address None.
Severity 4 (Information)
Source ExPro
90 Name MLXEV_PPILOT_SECONDARY_DISK_NOT_FOUND
Description A secondary logical drive was not found during initialization.
Cause PATHPilot reported a secondary logical drive was lost during power
cycle.
Action Investigate possible causes such as cabling, controller failure, or HBA
failure.
Address PATHpilot: Last HBTL: 12,13,14,15
Severity 4 (Information)
Source PATHpilot
Table 2 RAID Controller Event Codes