User Guide

© 2003, Adaptec, Inc. 145
81 Name MLXEV_SYSDEV_REBUILD_FAILED_ON_PARTNER
Description Rebuild stopped on controller failure.
Cause Rebuild moved to the surviving controller because the partner, which
was running the rebuild, failed.
Action None.
Address ctl: 0 logdrv: 15
Severity 4 (Information)
Source ExPro
82 Name MLXEV_SYSDEV_CHECK_CONSISTENCY_FAILED_ON_
PARTNER
Description Check Consistency stopped on controller failure.
Cause Check Consistency failed because the partner, which was running the
Check Consistency, failed.
Action Restart the Check Consistency.
Address ctl: 0 logdrv: 15
Severity 2 (Error)
Source ExPro
83 Name MLXEV_SYSDEV_FOREGROUND_INIT_FAILED_ON_
PARTNER
Description Foreground initialization stopped on controller failure.
Cause Foreground initialization failed because the partner, which was running
the foreground initialization, failed.
Action Restart the foreground initialization.
Address ctl: 0 logdrv: 15
Severity 2 (Error)
Source ExPro
84 Name MLXEV_SYSDEV_BACKGROUND_INIT_FAILED_ON_
PARTNER
Description Background initialization stopped on controller failure.
Cause Background initialization restarted on the surviving controller because
the partner, which was running the background initialization, failed.
Action None.
Address ctl: 0 logdrv: 15
Severity 4 (Information)
Source ExPro
85 Name MLXEV_CFG_COD_GROUP_NOT_INSTALLED_PDD_
USED
Description Configuration group not installed due to physical disk conflict.
Cause Physical disk already configured in another group.
Unable to map a physical device in this group.
Action Move to another controller.
Remove one or more existing configuration groups and reboot with this
group.
Address None.
Severity 4 (Information)
Source ExPro
Table 2 RAID Controller Event Codes