144 Spheras Storage Director Installation and User Guide
76 Name MLXEV_CFG_COD_DROPPED
Description A COD with unsupported features has been detected.
Cause Firmware does not support certain features in that COD.
COD import is to wrong system.
Action COD data is sequestered.
Obtain compatible firmware then reimport the COD or import the COD
to a different system.
Address ctl: 0
Severity 4 (INFORMATION)
Source InPro
77 Name MLXEV_CTLDEV_BBU_NEW_BATTERY
Description New battery found.
Cause Battery present in the controller could be a new or a replaced unit.
Action None.
Address ctl: 0
Severity 4 (INFORMATION)
Source InPro
78 Name MLXEV_CTLDEV_BBU_CHARGER_ERROR
Description Battery backup unit charger error.
Cause Battery backup unit failure.
Hardware problems in battery backup unit.
Action Replace the battery.
Replace the battery backup unit hardware.
If the problem persists contact your service representative.
Address ctl: 0
Severity 1 (Serious)
Source InPro
79 Name MLXEV_CTLDEV_BBU_BATTERY_ERROR
Description Battery will not hold a charge.
Cause Battery failure.
Action Replace the battery.
If the problem persists contact your service representative.
Address ctl: 0
Severity 1 (Serious)
Source InPro
80 Name MLXEV_FW_ENTERED_UNEXPECTED_STATE
Description Firmware entered unexpected state at run-time.
Cause Memory corruption.
Hardware returned unexpected value.
Action If the controller stops responding reboot and try again.
If problem persists contact your service representative.
Address ctl: 0 Version: 13.14-15 Param: 0x23222120
Severity 1 (Serious)
Source InPro
Paramtype enum
Params 0x90000001 : name_CHARGER_MANAGER : "Charger Manager
received unexpected state value"
0x90000002 : name_LOAD_POWER_GAUGE : "Load Power Gauge
State machine received unexpected state value"
0x90000003 : name_READ_CHARGE_LEVEL : "Read Charge Level
State machine received unexpected state value"
0x90000004 : name_READ_GAS_GAUGE : "Read Gas Gauge
received unexpected state"