User Guide
© 2003, Adaptec, Inc. 143
70 Name MLXEV_PHYSDEV_PORT_FAILED
Description Physical disk port has failed or cannot operate at the configured channel
speed.
Cause Physical disk hardware failure.
Physical disk is not compatible with system.
Enclosure disk slot hardware failure.
Action Replace physical disk.
Replace disk enclosure.
Address ctl: 0 chn: 13 tgt: 14
Severity 2 (Error)
Source ExPro
71 Name MLXEV_CTLDEV_MIRROR_RACE_ENTRY_FAILED
Description Mirror race recovery failed for logical drive.
Cause A read or write operation to a physical disk failed while restoring
redundancy.
Action Run consistency check and restore consistency.
Address ctl: 0 logdrv: 15
Severity 2 (Error)
Source ExPro
72 Name MLXEV_CTLDEV_CTRL_PARAMS_CHECKSUM_FAILED
Description Controller parameters checksum verification failed; restored default.
Cause NVRAM battery low.
NVRAM hardware failure.
Improper shutdown of the controller during controller parameter
update.
Action Restore correct controller parameter settings.
If problem persists, replace controller.
Address ctl: 0
Severity 2 (Error)
Source InPro
73 Name MLXEV_FIRMWARE_UPGRADE_STARTED
Description Online controller firmware upgrade has started.
Cause User has initiated an online firmware upgrade.
Action None
Address ctl: 0
Severity 4 (Information)
Source ExPro
74 Name MLXEV_FIRMWARE_UPGRADE_COMPLETE
Description Online controller firmware upgrade has completed successfully.
Cause Online controller firmware upgrade has completed without error.
The partner controller will now be auto flashed.
Action None
Address ctl: 0
Severity 4 (Information)
Source ExPro
75 Name MLXEV_FIRMWARE_UPGRADE_FAILED
Description Online controller firmware upgrade has failed.
Cause Online controller firmware upgrade has failed.
The original firmware will be reloaded.
Action Use the offline method to load the new firmware.
Address ctl: 0
Severity 2 (Error)
Source ExPro
Table 2 RAID Controller Event Codes