User Guide

© 2003, Adaptec, Inc. 141
59
Name MLXEV_PHYSDEV_MOVING_TO_OTHER_CHN
Description Physical disk is switching from one channel to the other channel.
Cause Physical disk removed or channel failed
Action Check Fibre Channel loop.
Replace physical disk if necessary.
Address ctl: 0 chn: 13 tgt: 14
Severity 3 (Warning)
Source ExPro
60 Name MLXEV_PHYSDEV_OFFLINE_DEVICE_MADE_ONLINE
Description Temporary-Dead physical disk is automatically made online.
Cause Temporary-Dead state caused because of transient errors
Action Analyze event log to find out why the physical disk was marked
DEAD.
Address ctl: 0 chn: 13 tgt: 14
Severity 2 (Error)
Source InPro
61 Name MLXEV_PHYSDEV_STANDBY_REBUILD_START
Description A standby rebuild has started.
Cause A physical disk failed and a spare was available.
Action None
Address ctl: 0 chn: 13 tgt: 14
Severity 4 (Information)
Source InPro
62 Name MLXEV_PHYSDEV_HOT_SPARE_SMALLER
Description Hot spare replaced with a smaller capacity physical disk.
Cause The new hot spare may have a smaller physical capacity than the
physical disk it replaced.
The controller coercion setting may have reduced the configurable size
of the new hot spare.
Action None
Address ctl: 0 chn: 13 tgt: 14
Severity 4 (Information)
Source ExP_old
63 Name MLXEV_PPILOT_LOGICAL_DISK_ONLINE
Description A storage access path has come online.
Cause PATHpilot reported an access path has become available.
Storage previously unavailable has become available again.
Action None
This indicates that storage access has been restored.
Address PATHpilot:
Curr HBTL: 12, 13, 14, 15
Severity 4 (Information)
Source PATHpilot
64 Name MLXEV_PPILOT_LOGICAL_DISK_OFFLINE
Description A storage access path has been lost.
Cause PATHpilot is unable to access certain storage on any path.
Storage previously available is now unavailable.
Action Investigate possible causes (such as cabling, controller failure, HBA
failure).
Address PATHpilot:
Last HBTL: 12, 13, 14, 15
Severity 1 (Serious)
Source PATHpilot
Table 2 RAID Controller Event Codes