User Guide
140 Spheras Storage Director Installation and User Guide
52 Name MLXEV_PHYSDEV_REBUILD
Description Physical disk status changed to rebuild.
Cause –
Action None
Address ctl: 0 chn: 13 tgt: 14
Severity 2 (Error)
Source ExPro
53 Name MLXEV_PHYSDEV_ID_MISMATCH
Description Physical device ID did not match.
Cause –
Action None
Address ctl: 0 chn: 13 tgt: 14
Severity 3 (Warning)
Source ExP_old
54 Name MLXEV_PHYSDEV_FAILED_START
Description Physical disk failed to start.
Cause –
Action Reseat the physical disk.
Replace the physical disk.
Address ctl: 0 chn: 13 tgt: 14
Severity 2 (Error)
Source ExPro
55 Name MLXEV_PHYSDEV_OFFSET_SET
Description Physical disk negotiated different offset than configured.
Cause –
Action None
Address ctl: 0 chn: 13 tgt: 14
Severity 3 (Warning)
Source ExP_old
56 Name MLXEV_PHYSDEV_SET_BUS_WIDTH
Description Physical disk negotiated different bus width than configured.
Cause –
Action None
Address ctl: 0 chn: 13 tgt: 14
Severity 3 (Warning)
Source ExP_old
57 Name MLXEV_PHYSDEV_MISSING_ONSTARTUP
Description Physical disk missing on startup.
Cause Physical disk missing.
Action Replace the physical disk or power-on all enclosures.
Address ctl: 0 chn: 13 tgt: 14
Severity 1 (Serious)
Source ExP_old InPro
58 Name MLXEV_PHYSDEV_REBUILD_START_FAILED
Description Rebuild startup failed due to lower physical disk capacity.
Cause Physical disk capacity not sufficient for rebuild.
Action Replace with a physical disk having sufficient capacity.
Address ctl: 0 chn: 13 tgt: 14
Severity 2 (Error)
Source InPro
Table 2 RAID Controller Event Codes