User Guide
138 Spheras Storage Director Installation and User Guide
39 Name MLXEV_PHYSDEV_SCSITMO_DEAD
Description A physical disk failed because a command to the disk timed out.
Cause SCSI command timed out on the device.
Action Replace physical disk and rebuild it.
Address ctl: 0 chn: 13 tgt: 14
Severity 1 (Serious)
Source InPro
40 Name MLXEV_PHYSDEV_SYSRESET_DEAD
Description A physical disk failed because of the system reset.
Cause System reset occurred.
Action Replace physical disk and rebuild it.
Address ctl: 0 chn: 13 tgt: 14
Severity 1 (Serious)
Source InPro
41 Name MLXEV_PHYSDEV_BSYPAR_DEAD
Description A physical disk failed because of busy status or parity error.
Cause The physical disk returned busy status.
The SCSI transaction with the physical disk met with parity error.
Action Replace physical disk and rebuild it.
Address ctl: 0 chn: 13 tgt: 14
Severity 1 (Serious)
Source InPro
42 Name MLXEV_PHYSDEV_BYCMD_DEAD
Description A physical disk set to failed state by host.
Cause Command from host set the physical disk to failed state.
Action Replace physical disk and rebuild it.
Address ctl: 0 chn: 13 tgt: 14
Severity 1 (Serious)
Source InPro
43 Name MLXEV_PHYSDEV_SELTMO_DEAD
Description A physical disk failed because access to the device met with a selection
time out.
Cause Physical disk disconnected or powered off.
Physical disk failure.
Action Replace physical disk and rebuild it.
Check power and cabling.
Address ctl: 0 chn: 13 tgt: 14
Severity 1 (Serious)
Source InPro
44 Name MLXEV_PHYSDEV_SEQERR_DEAD
Description A physical disk failed because of a sequence error in the SCSI bus
phase handling.
Cause Physical disk failure.
Action Replace physical disk and rebuild it.
Address ctl: 0 chn: 13 tgt: 14
Severity 1 (Serious)
Source InPro
45 Name MLXEV_PHYSDEV_UNKNOWNSTS_DEAD
Description A physical disk failed because device returned an unknown status.
Cause Bad physical disk or incompatible device.
Action Replace physical disk or the device and rebuild it.
Address ctl: 0 chn: 13 tgt: 14
Severity 1 (Serious)
Source InPro
Table 2 RAID Controller Event Codes