User Guide
© 2003, Adaptec, Inc. 137
32 Name MLXEV_PHYSDEV_INIT_CANCELED
Description Initialization canceled.
Cause User cancelled the operation.
Action Physical disk must be initialized again or the physical disk cannot be
used.
Address ctl: 0 chn: 13 tgt: 14
Severity 1 (Serious)
Source InP_old
33 Name MLXEV_PHYSDEV_WRITEREC_DEAD
Description A physical disk failed because write recovery failed.
Cause Write recovery process failed.
Action Replace physical disk and rebuild it.
Address ctl: 0 chn: 13 tgt: 14
Severity 1 (Serious)
Source InPro
34 Name MLXEV_PHYSDEV_RESET_DEAD
Description A physical disk failed because SCSI bus reset failed.
Cause SCSI bus reset failed.
Action Replace physical disk and rebuild it.
Address ctl: 0 chn: 13 tgt: 14
Severity 1 (Serious)
Source InPro
35 Name MLXEV_PHYSDEV_DBLCC_DEAD
Description A physical disk failed because double check condition occurred.
Cause Double check condition occurred.
Action Replace physical disk and rebuild it.
Address ctl: 0 chn: 13 tgt: 14
Severity 1 (Serious)
Source InPro
36 Name MLXEV_PHYSDEV_REMOVED_DEAD
Description A physical disk failed because disk is missing.
Cause Access to the physical disk failed.
Action Replace physical disk and rebuild it.
Address ctl: 0 chn: 13 tgt: 14
Severity 1 (Serious)
Source InPro
37 Name MLXEV_PHYSDEV_GROSSERR_DEAD
Description A physical disk failed because of gross error on SCSI processor.
Cause Gross error occurred to the on-board SCSI processor.
Action Replace physical disk and rebuild it.
Address ctl: 0 chn: 13 tgt: 14
Severity 1 (Serious)
Source InPro
38 Name MLXEV_PHYSDEV_BADTAG_DEAD
Description A physical disk failed because of invalid tag.
Cause The device responded with an invalid tag.
Action Replace physical disk and rebuild it.
Address ctl: 0 chn: 13 tgt: 14
Severity 1 (Serious)
Source InPro
Table 2 RAID Controller Event Codes