User Guide

© 2003, Adaptec, Inc. 135
21 Name MLXEV_PHYSDEV_COMMAND_RETRIED
Description SCSI command retried on physical disk.
Cause The command may have timed out.
Bus reset may have occurred.
Device reset may have occurred.
Action None
Address ctl: 0 chn: 13 tgt: 14
Severity 3 (Warning)
Source InP_old
22 Name MLXEV_PHYSDEV_PARITY_ERROR
Description Parity error found.
Cause A physical device did not generate proper parity.
The controller failed; did not check parity properly.
Cable failed.
Improper cable length.
Another physical device interfered.
Some outside environment affected the data on the cable (such as a
radio frequency signal).
Terminator is not connected.
Improper termination.
Action Refer to the enclosure manufacturers service manual.
Address ctl: 0 chn: 13 tgt: 14
Severity 2 (Error)
Source ExPro InP_old
23 Name MLXEV_PHYSDEV_SOFT_ERROR
Description Soft error found.
Cause An error was detected by a physical device and data was recovered.
Action Run consistency check.
If problem occurs frequently, replace the physical device.
Address ctl: 0 chn: 13 tgt: 14
Severity 3 (Warning)
Source InP_old
24 Name MLXEV_PHYSDEV_MISC_ERROR
Description Miscellaneous error found.
Cause A physical device reported some error that does not fit in any category.
Read/Write command time out.
Data over run.
Physical device was busy when host attempted to send command.
Action If problem occurs frequently, replace the physical device.
Address ctl: 0 chn: 13 tgt: 14
Severity 3 (Warning)
Source InP_old
25 Name MLXEV_PHYSDEV_RESET
Description SCSI device reset.
Cause Firmware has reset to recover from error.
User has reset.
Action None
Address ctl: 0 chn: 13 tgt: 14
Severity 4 (Information)
Source ExP_old InPro
Table 2 RAID Controller Event Codes