User Guide
134 Spheras Storage Director Installation and User Guide
15 Name MLXEV_PHYSDEV_UNCONFIGURED
Description A previously configured disk is now available.
Cause User set the physical device to unconfigured.
Action None
Address ctl: 0 chn: 13 tgt: 14
Severity 4 (Information)
Source InPro
16 Name MLXEV_PHYSDEV_EXPANDCAPACITY_START
Description Expand Capacity started.
Cause User started the RAID expansion operation.
A suspended RAID expansion operation was started.
Action None
Address ctl: 0 chn: 13 tgt: 14
Severity 4 (Information)
Source InPro
17 Name MLXEV_PHYSDEV_EXPANDCAPACITY_DONE
Description Expand capacity completed.
Cause RAID expansion finished.
Action None
Address ctl: 0 chn: 13 tgt: 14
Severity 4 (Information)
Source InPro
18 Name MLXEV_PHYSDEV_EXPANDCAPACITY_ERROR
Description Expand capacity stopped with error.
Cause Multiple physical devices failed.
Action It may not be possible to recover from this error.
Contact your service representative.
Address ctl: 0 chn: 13 tgt: 14
Severity 2 (Error)
Source InPro
19 Name MLXEV_PHYSDEV_COMMAND_TIMEOUT
Description SCSI command timeout on physical device.
Cause Physical device has been removed.
Physical device failed.
Command time out value is not correct.
Action Refer to the enclosure manufacturer’s service manual.
Address ctl: 0 chn: 13 tgt: 14
Severity 2 (Error)
Source ExPro InP_old
20 Name MLXEV_PHYSDEV_COMMAND_ABORT
Description SCSI command abort on physical disk.
Cause User may have requested to abort the command.
Firmware may have aborted the command to recover from error.
The physical disk may have aborted the command.
Action None
Address ctl: 0 chn: 13 tgt: 14
Severity 0 (Critical)
Source InP_old
Table 2 RAID Controller Event Codes