User Guide
© 2003, Adaptec, Inc. 133
9 Name MLXEV_PHYSDEV_REBUILD_ERROR
Description Rebuild stopped with error.
Cause Due to some unknown error on the controller, rebuild failed.
Action Try rebuild again.
Address ctl: 0 chn: 13 tgt: 14
Severity 2 (Error)
Source ExPro InPro
10 Name MLXEV_PHYSDEV_REBUILD_NEWDEV_FAILED
Description Rebuild stopped with error. New physical disk failed.
Cause New physical disk failed.
New physical disk may not be compatible with MDAC hardware/
firmware.
Action Replace the physical disk.
Address ctl: 0 chn: 13 tgt: 14
Severity 2 (Error)
Source ExPro InPro
11
Name MLXEV_PHYSDEV_REBUILD_SYSDEV_FAILED
Description Rebuild stopped because logical drive failed.
Cause At least one more physical disks failed in the array.
Bad data table overflow.
Action It may not be possible to recover from this error.
Contact your service representative.
Address ctl: 0 chn: 13 tgt: 14
Severity 2 (Error)
Source ExPro InPro
12
Name MLXEV_PHYSDEV_DEAD
Description A physical disk has failed.
Cause A physical disk failed.
A user action caused the physical disk to fail.
Action Replace the physical disk.
Address ctl: 0 chn: 13 tgt: 14
Severity 1 (Serious)
Source ExPro InPro
13
Name MLXEV_PHYSDEV_FOUND
Description A new physical disk has been found.
Cause A physical disk has been powered on.
A new physical disk has been added.
Controller was powered on.
Controller was added.
System has rebooted.
Action None
Address ctl: 0 chn: 13 tgt: 14
Severity 4 (Information)
Source ExPro InPro
14 Name MLXEV_PHYSDEV_GONE
Description A physical disk has been removed.
Cause User removed an unconfigured physical disk.
An unconfigured physical disk failed.
A controller was removed.
A controller powered off.
Action Replace the device if needed.
Address ctl: 0 chn: 13 tgt: 14
Severity 4 (Information)
Source ExPro InPro
Table 2 RAID Controller Event Codes