User Guide

© 2003, Adaptec, Inc. 131
Usually a non-optimal logical drive or physical device failure.
User action is needed to prevent data loss or loss of access to data.
User may need to replace hardware.
Resources in a serious state should be considered Vulnerable according to RAB guidelines.
6.9.4.3 Warning Icon:
An error has occurred that did not cause data loss, usually a software error. User may need to retry a command.
6.9.4.4 Informational or Optimal Icon:
A warning or condition that does not require immediate user action, but may become more serious.
Resources in the warning state should be considered Vulnerable according to RAB guidelines.
6.9.4.5 Events Icon:
Everything is good, no action is required.
Resources in an informational/optimal state should be considered Protected according to RAB guidelines.
6.9.5 RAID Controller Event Codes
Event
1 Name MLXEV_PHYSDEV_ONLINE
Description A physical disk has been placed online.
Cause Rebuild completed.
Physical disk was configured.
Manual online was done.
Action None
Address ctl: 0 chn: 13 tgt: 14
Severity 4 (Information)
Source ExPro InPro
2 Name MLXEV_PHYSDEV_HOTSPARE
Description A physical disk was added as a hot spare.
Cause Device was configured.
Manual hot spare was done.
Automatic hot spare was done.
Action None
Address ctl: 0 chn: 13 tgt: 14
Severity 4 (Information)
Source InPro
Table 2 RAID Controller Event Codes