User Guide
Chapter 3 JBOD Configurations36
This section describes the procedure for connecting the enclosure in
quad loop mode. For this configuration there must be two LS modules
and two I/O modules installed in the enclosure.
1 Remove both LS modules from the enclosure and install a jumper,
at jumper location JP3 if one is not already installed. This sets the
enclosure to operate in split loop mode.
2 Attach cables to the top and bottom connector of both I/O
modules (see Figure 3-4).
3 Attach the other end of these four cables to your host systems.
Figure 3-4 Cabling the Quad Loop Configuration
1
2
1
2
0
I
0
I
Loop A
Loop B
Drives 1-7
LSM
LSM
Drive 1
Drive 2
Drive 3
Drive 4
Drive 5
Drive 6
Drive 7
Drive 8
Drive 9
Drive 10
Drive 11
Drive 12
Drive 13
Drive 14
Drives 8-1
4
D
rives 1-7
Drives 8-14