User Guide
Installation
27
2.7.1 Configuring a RAID Controller to Use In-band SCSI
2.7.1.1 RAID Controller Adjustments
Some adjustments must be made to the RAID controller settings before the two can communicate
using SCSI commands. The RAID controller settings can be changed using the RS232.
You will need to make adjustments in the following four submenus: Peripheral Device Type,
Peripheral Device Qualifier, Device Support for Removable Media, and LUN Application. Different
host operating systems require different adjustments. Look at the table below to find the proper
settings for your host operating system.
7
From the Main Menu, press *
up
or
down
arrows to select “View and Edit
Configuration Parameters.”
View and Edit
Config Parms
Press <Enter>; and then use the *
up
or
down
arrows to select “Host-side SCSI
Parameters.” Then press <Enter>.
Host Side SCSI
Parameters . .
Table 2–2 Peripheral Device Type Parameters
Windows NT® 4.0 0x1f connected disabled All Undefined
LUNs
NetWare® 4.x/
Windows 2000/XP
0x03 connected disabled All Undefined
LUNs
SCO OpenServer
5.0x
0x7f connected either is okay All Undefined
LUNs
SCO
UnixWare 2.1x,
UnixWare 7
0x03 connected either is okay All Undefined
LUNs
Solaris™ 2.5.x/2.6
(x86 and SPARC)
0x7f connected either is okay All Undefined
LUNs
Linux 0x03 connected enabled All Undefined
LUNs
*
Up and Down
Arrows