Processor 5500 Series Datasheet, Volume 1 103
Thermal Specifications
6.1.2 Thermal Metrology
The minimum and maximum case temperatures (T
CASE
) are specified in Table 6-6,
through Table 6-13 and are measured at the geometric top center of the processor
integrated heat spreader (IHS). Figure 6-7 illustrates the location where T
CASE
temperature measurements should be made. For detailed guidelines on temperature
measurement methodology, refer to the Intel® Xeon® Processor 5500 Series Thermal
/ Mechanical Design Guide.
Notes:
1. Figure is not to scale and is for reference only.
2. B1: Max = 45.07 mm, Min = 44.93 mm.
3. B2: Max = 42.57 mm, Min = 42.43 mm.
4. C1: Max = 39.1 mm, Min = 38.9 mm.
5. C2: Max = 36.6 mm, Min = 36.4 mm.
6. C3: Max = 2.3 mm, Min = 2.2 mm
7. C4: Max = 2.3 mm, Min = 2.2 mm.
Figure 6-7. Case Temperature (T
CASE
) Measurement Location