User Guide
3
General Information
1.1 COMPANY INFORMATION
AccuTools Phone: (954) 227-0781
3650 Coral Ridge Drive Fax: (954) 227-1094
Suite 101 info@accutools.com
Coral Springs, FL 33065 www.accutoools.com
1.2 OPERATING INSTRUCTIONS
Everyone working with the BluFlame must carefully read and
understand these operating instructions before starting their
work. Always keep these operating instructions at the
BluFlame’s location of use.
These operating instructions are an important part of the package
and are not only intended to illustrate how to operate and use the
BluFlame, but also, and above all, to ensure the safety of its users and to
protect the environment. Accordingly, every user must familiarize themselves
with the contents of these operating instructions and follow all instructions
without fail.
When handing over the BluFlame to other parties, make sure to include the
operating instructions.
1.3 WARRANTY CLAIMS
Immediately check the initial shipment for damage in the presence of
the person delivering it. All damage must be confirmed by the person
delivering the shipment and reported within 3 days. Failure to do so will result
in your claim being denied.
This is a high-quality electronic measuring device. In order to
ensure that it will work for an extended period of time, the device
features low self-discharge rechargeable batteries. Accordingly, it is
recommended to charge the BluFlame after 2 to 3 months – even if it is not
used during this period, turn it on, and wait for the calibration phase to be
completed.
Keep the original box and the packaging material in case you need to send
in the BluFlame.
1.4 IMPORTANT INFORMATION
• The BluFlame is only suitable for short-term measurements.
• The BluFlame must be visually inspected before being turned on. This
visual inspection must also include checking for damage/soiling on the
probe, on the tube ports on the BluFlame, and on the condensate trap with
a star filter.
• When the BluFlame is turned on, it will automatically run a calibration
routine for its sensors (zeroing – please refer to section 6.8, “Turning on
and zeroing,” on page 13). Once this routine starts, and depending on the
sensors’ state, it will take about 1 to 3 minutes for the BluFlame to be ready
for operation.
• After zeroing, the required minimum time for a full correct measuring cycle
will be 1.5 minutes.
• Aggressive acidic atmospheres (sulfur) and vapors from alcohol
compounds (e.g., thinner, gasoline, ethanol, varnish) can ruin the sensors
in the BluFlame.
• The expected service life for the sensors is approx. 2 years for the O
2
sensor, approx. 2–3 years for the CO sensor, and approx. 3 years for the
NO sensor, with the actual service life depending on how the BluFlame is
used, maintained, and cared for.
• The service life of the rechargeable battery is at least 500 charge/discharge
cycles. The higher the number of cycles, the shorter the time that the
device will be able to run after the battery is recharged.
1.5 PACKAGING
Keep the original box and the packaging material so as to prevent transit
damage in case you need to send in the BluFlame to the factory.
1.6 PARTS CONTAINING HAZARDOUS MATERIALS
AND TAKE-BACK GUARANTEE
Accutools will take back any parts containing hazardous materials that have
been supplied by us and that cannot be disposed of “normally.”
The return shipment must be at no charge to Accutools. Parts containing
pollutants include, for example, electrochemical sensors, batteries, and
rechargeable batteries.
1.7 CUSTOMER FEEDBACK
The products described in these operating instructions are being
continuously developed and improved. Accordingly, we appreciate any
customer feedback, comments, and suggestions concerning our product and
these operating instructions that may help us improve our product, service,
and/or documentation.
Safety
2.1 INTENDED USE
The BluFlame measuring device is intended for short-term measurements within
the scope of emission checks and adjustment work on small-scale furnaces. The
BluFlame acquires readings and stores them for further processing.
The BluFlame must be used exclusively in conformity with the specifications
in these operating instructions.
Performing the actions specified in the “Maintenance and care” section at the
specified intervals is also an integral part of the device’s intended use.
Any other use will be considered an unintended use.
The following must be observed in particular within this context:
• Do not use the BluFlame as a safety device or as personal
protective equipment.
• Do not use the BluFlame as a warning device in order to warn people of
harmful gases.