Product Overview
BluVac+ Professional User’s Guide
9
Programming
As a special feature, the BluVac+ Pro includes two related programs: the Evacuation Program and
the Rise Time Testing (RTT) Program.
The Evacuation Program allows for unattended evacuation of large systems, and will sound an
audible/visual alarm when the evacuation procedure is complete, based upon both an Evacuation
Target Pressure and Evacuation Target Time. For example, a procedure may call for evacuating a
system to at least 500 microns, and maintaining that pressure (or less) for at least 15 minutes.
Following a successful evacuation, the RTT Program can consistently ensure proper evacuation by
analyzing the rate-of-rise of pressure vs. time, and automatically signal a or indication
based upon an RTT Target Pressure and RTT Target Time. Advantageously, a clean, dry, and tight
system can successfully a Rise Time Test in as little as 15 seconds, eliminating the need to wait
for the RTT Target Time to elapse. For example, a procedure may call for ensuring that a system
evacuated to 500 microns or less will not exceed 1000 microns after the vacuum pump has been
blanked off over 10 minutes.
Each program consists of both a target pressure (vacuum level) and a time period. There are 16
possible target pressures, depending upon the units displayed, as shown in the following table:
Units
Microns Pascal Millibar Millitorr mmHg PSI inHg
50 5.0 0.050 50 0.050 0.0010 -29.919
75 10.0 0.100 75 0.075 0.0015 -29.918
100 15.0 0.150 100 0.100 0.0020 -29.917
150 20.0 0.200 150 0.150 0.0030 -29.915
200 30.0 0.300 200 0.200 0.0050 -29.913
300 50.0 0.500 300 0.300 0.0075 -29.910
500 75.0 0.750 500 0.500 0.0100 -29.900
750 100.0 1.000 750 0.750 0.0150 -29.890
1000 150.0 1.500 1000 1.000 0.0200 -29.880
1500 200.0 2.000 1500 1.500 0.0300 -29.060
2000 300.0 3.000 2000 2.000 0.0500 -29.850
3000 500.0 5.000 3000 3.000 0.0750 -29.800
5000 750.0 7.500 5000 5.000 0.1000 -29.700
7500 1000.0 10.000 7500 7.500 0.1500 -29.600
10000 1500.0 15.000 10000 10.000 0.2000 -29.500
15000 2000.0 20.000 15000 15.000 0.3000 -29.300
The time periods may be programmed between 0 seconds and 100 minutes. The BluVac+ Pro can
be programmed easily through the mobile app. To program the BluVac+ Pro manually, the Set Mode
must be activated:
Programming (Set Mode)
1. Turn the power on by pressing .
2. Select the desired units by repeatedly pressing .
3. Activate the Program Set Mode by pressing and holding . The and indicators will
show on the display, as well as the currently programmed Evacuation Target Pressure and
Time.
4. While the pressure display is flashing, press and/or hold the or keys to increase or
decrease the Evacuation Target Pressure. When compete, press and release the key.
5. While the minutes display is flashing, press and/or hold the or keys to increase or decrease
the Evacuation Target Time minutes. When compete, press and release the key.
6. While the seconds display is flashing, press and/or hold the or keys to increase or
decrease the Evacuation Target Time seconds. When compete, press and release the key.
7. The display will now show the currently programmed RTT Target Pressure and Time, and the
indicator will illuminate