DS-220 Versatile Digital Scale User’s Guide
DS-220 User’s Guide Introduction Thank you for your purchase of the AccuTools™ DS-220 Versatile Digital Scale. The DS220 is the most accurate and precise digital scale available today with features that cannot be found anywhere else. With the DS-220, you can measure weight or liquid volume in both metric and English units, in addition to using it as a parts counter. The DS-220 is also programmable, and has a built in alarm to indicate a programmed threshold has been exceeded.
DS-220 User’s Guide Parts Diagram LCD Display Easel (Extended) Keypad Coiled Cord Storage Dock Weighing Platform Easel (Retracted) Mounting Hooks Speaker Grill Optical Port for CM-500 Battery Cover Control Box Rear View 2
DS-220 User’s Guide LCD Display C B A D F G E H I J K L M N Item 3 O P Q R Function A Measurement Mode Indicators B Specific Gravity Indication (only in Liquid Measurement Mode) C Alternate Numeric Display (for Specific Gravity or Tank Capacity) D Tank Capacity Percent Indication E Units Indicators F Main Numeric Display G Key “Beep” Indicator H “Floating” Negative Indicator (Indicates weight removed from platform) I Battery Level Indicator J Fast Adjustment Indicator K
DS-220 User’s Guide Keypad Press for power-on, press/hold for power off, press/release for backlight. Press to cycle through weighing modes. Press to cycle through displayed units. Press to select low, medium, or high display resolution. Press to tare (“zero-out”) current reading on display. . Use to adjust various settings and programming values. For faster adjustments. Used in conjunction with and . Starts Count Mode training. “Freezes” display.
DS-220 User’s Guide Quick Start To operate the DS-220 as a basic weigh scale, perform the following steps: Setup 1. Unpack the scale as described in the “Unpacking the DS-220” section below. 2. Install the batteries into the control box as described in the “Battery Installation” section below. 3. Place the Weighing Platform on a firm, level surface. 4. Turn the DS-220 on by pressing . 5. If desired, turn on the backlight by momentarily pressing 6. Select the weigh mode by repeatedly pressing follows: .
DS-220 User’s Guide Basic Operation 1. If using a container to hold the objects or liquids being measured or counted, place it empty on the center of the platform. 2. Press to “zero-out” the scale. The display will read zero. 3. Place the material to measure in the container or on the center of the platform. 4. Read the weight, volume, or number of items on the display. 5. A positive number indicates the applied weight is greater than the zero value.
DS-220 User’s Guide Battery Installation & Replacement 1. Remove the battery cover from the rear of the control box by compressing tab at the base of the battery cover. 2. If necessary, remove old set of batteries. 3. Insert 4 ‘AAA’ Alkaline batteries. Replace battery cover by aligning tabs and snapping back into place. IMPORTANT: TO PREVENT DAMAGE TO THE DS-220, CAREFULLY OBSERVE BATTERY POLARITY AS MARKED INSIDE THE BATTERY COMPARTMENT. DO NOT LEAVE DEAD BATTERIES INSIDE THE CONTROL BOX.
DS-220 User’s Guide Over range Indication If the weight applied to the weighing platform exceeds the maximum capacity of the DS-220 (100 kg), a single “1” will be shown on the left side of the display. To prevent damage to the DS-220, immediately remove the weight from the platform. Measuring Weight Measuring Weight with the DS-220 is straight forward: 1. Set up the DS-220 as described in the QUICK START Setup section above. 2. Select WEIGHT using . 3. Select the desired units of measure using 4. Use .
DS-220 User’s Guide Determining Specific Gravity It is possible to determine the specific gravity of a liquid if you already know its volume. Using a graduated container appropriate for the liquid in question, perform the following steps: 1. Ensure the DS-220 is in VOLUME SPECIFIC GRAVITY MODE (refer to the Quick Start section). 2. Place the empty graduated container to the center of the platform. 3. Press to “zero-out” the weight of the container. The display will read zero. 4.
DS-220 User’s Guide Counting The DS-220 can count items of equal weight. In order to count accurately, the scale must be “trained” to recognize the weight of the items being counted. To train the DS-220 for counting, perform the following steps: 1. Set up the DS-220 in counting mode as described in the Quick Start Setup section. 2. Remove all objects from the weighing platform. 3. If a bin is going to be used to hold the items being counted, place the empty bin on the center of the platform. 4. Press .
DS-220 User’s Guide Hold Mode A special feature of the DS-220 allows the emptying or replacing bins or containers used for weighing or counting without affecting the weight shown on the display. This Hold Mode may be used as follows: 1. In any weigh mode, allow load to settle until display is steady. 2. Press . The HOLD indicator will turn on and current weight is now locked on the display. 3. Remove, empty, or replace objects, bins, or containers on the platform. 4.
DS-220 User’s Guide 6. When the applied (or removed) weight exceeds the programmed amount, the alarm will sound and the DONE indicator will flash on the display to indicate the program is complete. 7. Press any key to stop the alarm. 8. To cancel the RUN mode at any time, press the key. NOTE: The RUN mode can only be initiated from the SET mode. If you cancel the RUN mode by pressing by , and wish to RUN again, press (the previous set point will be restored) followed again.
DS-220 User’s Guide 5. Apply a full container (or a load representing the weight of a full container) on the platform. Wait 5 seconds for the load to stabilize, then press and the SET TANK indicator will turn off. . This completes the training process, 6. From this point forward, the Alternate Numeric Display will show the percent of material remaining in the container from 0% to 100%. NOTE: The 100% weight must be larger than the 0% weight by at least 200g.
DS-220 User’s Guide Battery Level Indicator The battery level indicator shows the relative strength of the batteries. Full power is indicated by four bars. As the batteries are depleted, the number of bars displayed decreases, until no bars are left. At this point, it is necessary to replace the batteries (refer to the Battery Installation section above).
DS-220 User’s Guide Restoring Factory Calibration If you make a mistake recalibrating the DS-220, you can always restore the factory calibration (and factory defaults) of the scale. To restore the factory settings perform the following steps: 1. Turn the power to the DS-220 off. 2. Remove any objects from the platform. 3. While holding , press and release The factory settings are now restored. . The DS-220 will turn on and 10 beeps will sound. 4.
DS-220 User’s Guide Applications This section deals with specific applications for which the DS-220 may be used. HVAC Service Because of its high stability and accuracy, the DS-220 is ideal for automotive, commercial, and residential A/C refrigerant charging and recovery. Its high resolution also allows accurate critical charging of small refrigeration systems such as commercial freezers. To use the DS-220 for refrigerant charging, perform the following steps: 1.
DS-220 User’s Guide Appendix Specific Gravity of Common Materials Fluid Acetic Acid Acetone Alcohol, ethyl Alcohol, methyl Alcohol, propyl Ammonia (aqua) Aniline Benzene Benzil Butane Caproic acid Carbolic acid Carbon disulfide Carbon tetrachloride Carene Chloride Chloroform Citric acid Creosote Cresol Crude oil, California Crude oil, Mexican Crude oil, Texas Cumene Decane Dodecane Specific Gravity 1.052 0.787 0.789 0.802 0.826 1.022 0.876 1.084 0.601 0.924 0.959 1.265 1.589 0.860 1.560 1.469 1.665 1.
DS-220 User’s Guide Warranty and Repair 1 Year Limited Warranty Core Enterprises, Inc. warrants that this AccuTools™ product conforms to Core Enterprises, Inc. published specifications and will be free from defects in material and workmanship. The duration is for a period of one year from the date of purchase. Core Enterprises, Inc., at its option, will repair or replace this product or any component of the product found to be defective during the warranty period.
3650 Coral Ridge Drive, Suite 101 Coral Springs, FL 33065 Ph: (954) 227-0781 • Fax: (954) 227-1094 www.accutools.com AccuTools™ is a trademark of Core Enterprises, Inc. P/N 10154 Rev.