Instruction Manual

4. How to Use
User Guide Page 4-47
4.1.2.8.6 Health Center
To ensure the accuracy of the RAID parity data, ExaSAN RAID controller offers
Background checking and “Rebuild parity data”. During checking or rebuilding parity,
the performance of the array will be affected. You may check the progress of in the
Main view or in the Health Center.
Follow the steps below to select an array to verify, rebuild, or condition.
1. Select the Array to verify, rebuild, or condition.
2. Click the radio button to:
Rebuild the parity dataRebuilding parity on an array uses the data on the array to
create new parity data, no repair problems with the data.
Verify the parity data Verify that the data is free of errors.
Refresh array data and paritySelect the priority between Low, Med., or High. This
process scans, rewrites, and scrubs bad data conditions caused by excessive
vibration during drive I/Os, or data degradation caused by Adjacent Track
Interference (ATI).
3. Click OK to start the operation.