Instructions / Assembly

STEP 1
STEP 2
STEP 3
STEP 4 CHECKLIST
STEP 5
STEP 2
PREPARE THE HOUSE FOR TESTING
SELECT THE TEST AREA
PERFORM THE TEST
COMPLETE THE DATA SHEET FOR A SUCCESSFUL TEST
RETURN DEVICES IMMEDIATELY!!
In order to provide a valid test result, the test must be
performed under Closed House Conditions. Maintain
these conditions in the home for 12 hours before the test
and during the exposure period:
• Keep all exterior doors closed except for normal
entry and exit.
• Keep all windows closed.
• Leave radon mitigation systems operating.
• Set HVAC Systems on “Auto” and set window units
to recirculate. Dehumidiers may be operated.
• Do not operate whole house exhaust fans.
• Do not operate wood or coal stoves (unless they are
the primary source of heat).
Unusual weather conditions could alter test results.
Do not perform the test during sustained high winds or
heavy rain. Do not test in extreme indoor conditions of
heat, cold or humidity.
• Do not test in closets or crawl spaces.
Find a location that is at least 3 feet from any door, wall
or window, 2 feet from the oor or ceiling, and 4 inches
from other objects.
• Do not place test devices directly under blowing air.
• If this test is associated with the purchase or sale of
a home, the EPA Real Estate Simultaneous Testing
Protocol recommends 2 devices to be placed side
by side, 4 inches apart in the selected test area.
Do not open the devices until you are ready to test.
• Check devices for expiration dates. Start your test
before device expires or results will be invalid.
• Remove test devices from the box. Take off the lid from
each test device. Save the box for returning devices to
the Lab.
Leave each device open for at least 48 hours. Do not
touch or move devices during the test.
If you leave devices open for less than 48 hours or
more than 96 hours the results will be invalid. You will
need to buy another test kit and repeat the test.
After 48 hours, securely replace the lid of each device.
• If using the metal charcoal canister, replace the original
lid and wrap the tape provided around the closed
canister where the base meets the lid. Do not cover
device numbers with tape.
It is very important to fully complete the Radon Test
Data Sheet on the other side of this form. Please
write neatly.
To access a copy of your radon test report at
www.accustarlabs.com, you must write the Zip Code
of the Property Tested on the Radon Test Data Sheet.
Note: If information is missing from the Data Sheet, or if
you do not send back the Data Sheet with the devices,
you will receive a report stating that we cannot provide
your test results. You may send any missing information
to us in writing at a later time (mail, email or fax required)
and we will issue an Amended Test Report.
Amended Test Reports take 5 business days.
However, if you need a Same-Day Amended Test
Report please call the lab at 888-480-8812. There is an
additional fee for a Same-Day Amended Test Report,
payable by credit card.
Did you follow all instructions and ll out the Data
Sheet completely?
Did you keep a record of your device number(s) and
the Zip Code of the property tested?
Did you send your test kit with the completed Data
Sheet to AccuStar Labs immediately after you
nished the test?
Place closed test devices and the completed Data Sheet
back into the box and send it to AccuStar right away.
AccuStar must receive the test devices within 8 days
after you complete the test.
Your test results will be invalid if we receive test devices
more than 8 days after you complete the test.
Test Results 24 Hours A Day
Call our Radon Test Results Line at 888-404-3144 to check
whether we received your kit, and for verbal test results.
You must have your device numbers to receive test results.
On the next business day after AccuStar receives the test
kit, we will e-mail or mail your radon test report to the person
indicated on the Data Sheet. You can access a copy of the
report on our website www.accustarlabs.com.
Feel free to call us at 888-480-8812 with any questions you
may have. Our business hours are 8:30 am to 5:00 pm Eastern
Time, Monday – Friday.
Thank you for choosing AccuStar Labs.
• Perform the test in the lowest area of the home
that could be used regularly, whether it is nished
or unnished.
Choose an area that could be used as a bedroom, play
area, family room, den, exercise room, or workshop, but
not a kitchen or bathroom or any area with high humidity.
(continued)
(continued)
Radon Test Data Sheet
Tel: 888-480-8812
Fax: 508-533-8831
24 Hour Test Results: 888-404-3144
www.accustarlabs.com
1st CLASS MAIL DELIVERY IS NOT GUARANTEED
Most test kits sent to us via 1st Class Mail arrive at the Lab within 3 to
5 days. However, if you need guaranteed delivery we recommend that
you send your kit using FEDEX, UPS or EXPRESS MAIL.
If delivery of your kit is delayed more than 8 days, AccuStar Labs is
not responsible for invalid results or for a free replacement test kit.
DISLAIMER
These instructions cannot anticipate or address every condition that
arises when performing a radon test. Some states have specic
regulations regarding radon testing. If you have questions about your
state’s requirements please contact your State Radon Ofce.
IMPORTANT! KEEP FOR YOUR RECORDS
Write each device number and the Zip Code of the property tested here.
AccuStar Labs
11 Awl St.
P.O. Box 158
Medway, MA 02053 USA
Device Number Device Number
Zip Code