Troubleshooting guide
16
HOOD SECTION VIEW
DEFLECTOR TO BE PLACED CENTERED
UNDER THE SUPPLY DUCT COLLAR
SU
PPL
Y
FIRE DAMPER
INTERNAL
SU
PPL
Y
C
HAMBE
R
H
OO
D
IN
SU
LATE
D
SU
PPLY PLEN
UM
EXHA
UST
C
APT
U
RE
SU
PPLY L
OC
ATI
O
N DETAIL F
OR
A
IR 
CU
RTAIN AND 
CO
MBINATI
ON
Hanger Bracket
Exhaust Plenum
Duct Cut Out Area
Duct Cut Out Area
Supply Plenum
Hood Length
Hood Width
Front of Hood
Exhaust Plenum
8.00 8.00
8.00
3.00
3.00
16.00
14.00
8.00
1.00
12.00
A
 C
O
N
T
INU
O
U
S
L
I
Q
UID 
T
I
G
H
T
 W
E
L
D 
T
O
 H
OO
D.
E
X
H
A
U
S
T
 DUC
T
 C
O
NN
E
C
T
I
O
N I
S
T
O
B
E
C
O
NN
E
C
T
I
O
N
E
X
H
A
U
S
T
 DUC
T
F
R
O
N
T
O
F
 H
OO
D
H
A
N
G
E
R
BR
A
C
K
E
T
E
X
H
A
U
S
T
 P
L
E
NUM
E
X
H
A
U
S
T
 P
L
E
NUM
S
UPP
L
Y
 P
L
E
NUM
DUC
T
 CU
T
O
U
T
A
R
E
A
LABELED SUB-ASSEMBLY FOR EXHAUST HOOD WITHOUT EXHAUST DAMPER PART NO. DC.
2. U.L. LISTED HOOD ASSEMBLY TO BE USED ONLY WITH GREENHECK FAN CORP.
CENTER OF HOOD LENGTH TO CENTER OF DUCT CONNECTION.
NOTES: 1. EXHAUST DUCT CONNECTION TO BE LOCATED WITH IN 48" FROM
1
"
T
O
 2
"
T
A
C
K
S
O
R
S
H
EE
T
 M
E
T
A
L
S
C
R
E
W
S
A
T
 3
"
T
O
6
"
S
P
A
CIN
G
T
O
 H
OO
D.
S
UPP
L
Y
 DUC
T
 C
O
NN
E
C
T
I
O
N 
T
O
B
E
T
A
C
K
 W
E
L
D
E
D WI
T
H
C
O
NN
E
C
T
I
O
N
S
UPP
L
Y
 DUC
T
DUC
T
 CU
T
O
U
T
A
R
E
A
Hanger Bracket
Exhaust Plenum
Duct Cut Out Area
Duct Cut Out Area
Supply Plenum
Hood Length
Hood Width
Front of Hood
Exhaust Plenum
8.00 8.00
8.00
3.00
3.00
16.00
14.00
8.00
1.00
12.00
Back View of the Hood
Fig 25
Fig. 26 Fig. 27
Fig. 28
  Note: UL listed hood 
assembly to be used 
only with Accurex, LLC 
labeled subassembly 
for exhaust hood 
without exhaust 
damper part 
Number DC.
Hood Top
1.  The exhaust duct 
connection needs to 
be located within 48 in. 
(121.92 cm) from the 
center of the hood 
length to the center of 
the duct connection. 
(see Fig. 24, back view 
Fig. 25)
2.  The exhaust duct 
connection is to be 
a continuous liquid- 
tight weld. Weld with 
a non-ferrous filler 
wire, such as silicon 
bronze or stainless 
steel filler wire. Protect 
all stainless steel areas 
from weld splatter.
3.  The supply duct 
connection is tack-
welded at 1 to 2 in. 
(2.54 to 5.08 cm) 
intervals, or sheet metal 
screws at 3 to 6 in. 
(7.62 cm to 15.24 cm) 
spacing to the hood. 
(Fig. 26)
4.  The deflector is 
centered under the 
supply duct collar. 
(Fig. 28)
5.  For hoods that are 
insulated, the edges of 
the insulation need to 
be taped after the hole 
is cut, (the insulation 
tape is to be provided 
by others).
6.  On combination hoods, 
make sure the fire 
damper is located over 
the internal supply 
chamber. (Fig. 29)
Top View of the Hood
Fig. 24
Installing Duct Collars