User manual

ProScale RF Receiver User Manual Page 16 of 17
Output mode 5 position packet message, position 8.537 inches from display unit
ID 1, signal strength 5, message 34.
Byte Number Value Description
1 255 Destination address (receiver)
2 1 Display address ID
3 ‘A’ Position command character ASCII A
4 ‘5’ Signal strength ASCII 5
5 34 Message ID
6 13 Number of data bytes to follow
7 1 Always 1
8 0 Always 0
9 1 Always 1
10 1 Always 1
11 1 1 = inches, 0 = mm
12 ‘ ‘ space if positive, ‘-‘ if negative
13 ‘ ‘ hundreds digit
14 ‘ ‘ tens digit
15 ‘8’ ones digit
16 ‘.’ decimal point
17 ‘5’ tenths digit
18 ‘3’ hundredths digit
19 ‘7’ thousandths digit
Output mode 5, “delete previous measurement”, from display unit ID 1, signal
strength 7, message 21.
Byte Number Value Description
1 255 Destination address (receiver)
2 1 Display address ID
3 ‘I’ Delete measurement command, ASCII I
4 ‘7’ Signal strength ASCII 7
5 21 Message ID
6 0 Number of data bytes to follow
All values in binary except ASCII values where noted.