Instruction manual

56
Product Communication:
ProScale's electrical interface allows the readhead position to be read by
a computer or other instrument. Interface diagrams are available upon
request.
Error Codes & Factory Service
ProScale warns if an error occurs by displaying "Err" plus a number on
the display. If error code 0, 1, 2, 3, 5, 6, 7, or 8 is displayed:
1. Check to be sure the readhead is on the scale.
2. Check all connections and cable for damage.
3. If the readhead is on the scale and all connections are good, unplug
the readhead from the display , wait 3 seconds, and reinstall it.
If error code 4 is displayed, the display is trying to display fractions over
99 63/64". Switch to a decimal readout or press ZERO (and recalibrate)
if this value is incorrect.
For further assistance, contact your supplier, or Accurate Technology.
When calling for factory service, please have as much information about
your product on-hand. If possible, please have the following information:
1. Product name.
2. Any modification to the product.
3. The date of product purchase.
4. Detailed information about the problem, such as when, where, and
how the problem occurs, and the machinery being used nearby.