and show the next parameter value (right side). After the ninth
parameter, pressing the MODE key will restart the parameter list at 1.
To exit the programming mode, press and hold the MODE key, then
press the ZERO key.
The programming parameters and the valid parameter values are shown
in the following chart:
Parameter Option Valid Parameter Values
Option 1
Measurement Units
0 = millimeters
1 = decimal inches
2 = Fractions, 16ths
3 = Fractions, 32nds
4 = Fractions, 64ths
Option 2:
Enable/Disable Offsets
0 = Offsets can not be entered
1 = Offsets can be entered
Option 3:
Enable/Disable Multi-Pattern Scales
(Must be enabled for scales over 17")
0 = Multiple Scale Patterns not recognized
1 = Multiple Scale Patterns allowed
Option 4:
Encoder Direction (changes sign)
0 = Positive readings
1 = Negative readings
Option 5:
Enable/Disable HOLD Feature
0 = HOLD feature is disabled
1 = HOLD feature is enabled
Option 6:
Automatic Power-off Timer
0 = Automatic Power-off is disabled
1-255 Number of minutes until power-off
Option 7:
INC Mode Operation
0 = Disables INC mode; ABS mode only
1 = Allows kerf values in INC mode
2 = Uses INC mode as 2
nd
coordinate system
Option 8:
Scaling Multiplier
Scaling multiplier can be from 0.01 to 99.999
Default value is 1.000
Option 9:
Position Change Needed for Wake-up
(must be set in mm)
Valid range is .1mm to 99.9mm
Default is 2.0mm
Setting ABS Position
When the display is in ABS mode (indicated by ABS in the upper left
corner of the display), a zero point is established by pressing the ZERO
key. All subsequent absolute measurements will reflect distance from
this point. The display should be locked to prevent accidental resetting.
Setting INC Position
Momentarily press the MODE key. This switches the display to
incremental mode. Press the ZERO key. Any measurement now taken
will be an incremental measurement. The display can be repeatedly re-
zeroed (for incremental measurements) by pressing the MODE key (for