Instruction manual
23
5. Press and hold the PLUS key to scroll until the measurement is
displayed (the longer the PLUS key is held down, the faster the
display will scroll).
6. When the proper reading is reached, lock the display if desired. This
prevents accidentally re-zeroing of the display. See Section 3 for
more information about how to lock the display.
7. Re-calibrate, if necessary, after changing saw blades (or applicable
tooling).
8. Calibration is also necessary after display batteries are changed.
Maintenance:
1. The fence extrusion should be cleaned of all debris periodically. Do
not use any liquid lubricants on the scale assembly, as this may:
a. Impede the readhead's ability to operate properly.
b. Attract other contaminants to the scale.
2. Should the stop become difficult to move, and the fence and scale
have both been cleaned, the plastic wing may need adjustment:
a. Position the wing to hold the locking
mechanism of the stop in the center
of the extrusion slot.
b. The position of the wing can be
adjusted after removing the plastic
guide clip and loosening the socket screws (using a 3/16" hex
wrench) which sandwich the wing between the stop and the
aluminum block.
c. The wing is adjusted properly when the weight of the stop is
supported by the wing and the locking mechanism does not rub
on the extrusion.
3. The Digital Display should be cleaned periodically with compressed
air to remove any dust on the lens and keys. All fasteners should
occasionally be checked for tightness.
4. To change the batteries, remove the two screws that hold the cover
to the base of the digital display. Remove the top cover carefully.
Install two AA size alkaline batteries, noting the proper orientation
shown in the battery compartment. Replace the cover and tighten
the screws.