Instruction manual

15
The Display should be mounted in a location which allows for easy
viewing by the machine operator. The location of the parts should
also safeguard the cable from possible damage. All ProScale wiring
should be kept as far away as possible from the machine’s wiring
and motors and dust collection systems. Avoid running the
readhead wiring parallel to high voltage/current wiring.
3. Mount the readhead using three screws or bolts. It may be
necessary to use washers or spacers to ensure a good mount (if the
readhead is to be mounted on an uneven surface).
4. Check that the scale is properly aligned with the direction of motion
of the moving part. The connector link will compensate for only a
small amount of misalignment. The connector link must be mounted
in the same direction as the scale (as in the figure below).
Note: Failure to use the connector link will void the warranty.
5. Mount one end of the connector link to the scale using an M5 (or 10-
32) screw and the other end to the moving part of the machine.
Check that both connections are very secure; inaccurate/erratic
readings may otherwise occur.
6. Plug the readhead into the display. See Section 3 regarding
mounting and use of different display versions.
MOVING PART OF MACHINE
DISPLAY
CONNECTOR LINK
MOVEMENT
A Typical Model 150 Installation
READHEAD