Installation manual
Operation Manual for LCD Digital Readouts Page 42 of 48
Pr 26 – Position Monitor Drift Tolerance. [.0004” to 120”, .01”]
This parameter sets the amount of drift that must occur in MONitor mode to
trigger a drift condition indication.
Default = .01”
Pr 27 – Use Soft Limits. [0 or 1]
Enables or disables the use of soft limits. If enabled, a message on the LCD is
displayed when the measuring system is operating outside the programmed
(Pr 28 & Pr 29) position limits. 0 = off, 1 = on.
Default = 0 (off)
Pr 28 – Lower Soft Limit Position. Range: Any displayable position.
Defines the position to be used as the lower limit if the Use Soft Limits
parameter is enabled (Pr 27=1).
Default = 0.000
Pr 29 – Upper Soft Limit Position. Range: Any displayable position
Defines the position to be used as the upper limit if the Use Soft Limits
parameter is enabled (Pr 27=1).
Default = 5.000”
Pr 30 – Offset Addition Enable. [0 to 4, 0]
Enables or disables offset addition function. This feature allows the user to
choose from up to 4 programmed values that can be added to the current
position using the F1 key.
1 = Offset 1 enabled 2 = Offsets 1 & 2 enabled
3 = Offsets 1, 2 & 3 enabled 4 = Offsets 1, 2, 3 & 4 enabled
Default = 0 (Disabled)
Pr 31 – Offset Addition Preset 1. Range: Any displayable position
This value is added to the current ABS position when Offset Addition is enabled
(Pr 30 not set to 0) and Offset Preset 1 is selected with the F1 key.
(1
1 1
1 segment displayed on LCD).
Default = .5” (12.7mm)
Pr 32 – Offset Addition Preset 2. Range: Any displayable position
This value is added to the current ABS position when Offset Addition is enabled
(Pr 30 not set to 0) and Offset Preset 2 is selected with the F1 key.
(2
22
2 segment displayed on LCD).
Default = 2” (50.8mm)