Installation manual

Manual Part # 800-1402-001 Rev E Page 25 of 48
Hold: F4
The Digital Readout provides a feature that allows the displayed position to be
“frozen” in time while the Encoder is moved from its current position. This
allows measurements to be captured on the Digital Readout and held for later
viewing regardless of the current Encoder position. To activate the Hold Mode,
momentarily press the F4 key. HOLD
HOLDHOLD
HOLD will be displayed in the upper left corner of
the LCD. The currently displayed position and selected key presses will be
frozen at this point. To release the HOLD feature, momentarily press the F4
key again, or cycle power.
NOTES: If power is cycled when Hold Mode is active, any key (such as
UNITS, DATUM, + or –) that was depressed while in Hold Mode will be
executed when power is restored.
Leaving the normal measurement mode, (enter programming mode, send
data transmission, or using the Go/No Go editor) causes the DRO to
automatically exit Hold mode.
Delete: F2
Momentarily pressing F2 sends a special “delete” signal to the SPC data port.
When a ProRF Transmitter is attached to the port, a “delete” message will be
sent to the ProRF Receiver. This “deletemessage removes the last
measurement from the cut list when connected to a TigerStop® controller.