User`s manual

ProScale M150, M250 and all products with General Purpose LCD Digital Displays 31 of 44
Programming
Several functions of the digital display are user programmable. The following instructions
describe what features are available and how to change the system’s factory defaults to
customize the display for your application.
The keys pictured have multiple functions. Timing, which is how long a key is depressed,
and the combination of the keys pressed is important. This manual uses the term
‘”momentarily” to describe a key press of typically less than 1 second. Whereas “press
and hold” is used imply a key press of typically longer than 1.5 seconds. As an example;
when using a PC keyboard to type a CAPITAL letter you would press and hold” the
SHIFT key andmomentarily depress the appropriate letter key.
Thefunction” associated with the key(s) pressed is executed on the key RELEASE, not
the key DEPRESS. This is important since some keys execute different functions based
on how long they are depressed. These key operations, once tried, quickly become
intuitive.
To enter programming mode, press and hold the MODE key and then momentarily press
the 0 (zero) key. The MODE key must be held for approximately 1 second before the
depression of the 0 (zero) key.
Once you are in the Programming Mode, momentarily pressing the MODE key will
advance through the Programming Parameter list.
To step backwards in the Programming Parameter list press and hold the ON/OFF key
and momentarily press the MODE key.
Momentarily pressing the + (plus) key while displaying a Programming Parameter will
increase the parameter setting.
Momentarily pressing the - (minus) key while displaying a Programming Parameter will
decrease the parameter setting.
Momentarily pressing the 0 (zero) key while displaying a Programming Parameter will
revert the parameter to its factory default setting.
CAUTION: The Limit Mode (See Programming Parameters 14,15 16 17) functionality is
still active even while the display is in programming mode. Changing LIMITS may result
in the Limit/Monitor Signal hardware output becoming active immediately.
To exit programming mode, press and hold the MODE key and then momentarily press
the 0 (zero) key.
NOTE: The display will automatically exit programming mode after 60 seconds of no key
activity.