User manual

Accurate Technology Digi Fence Page 7 of 16
Calibration
There are two ways to set a zero reference (calibration).
Quick Method: Move the fence until it just touches the blade and depress the Zero
key on the front of the digital readout.
Best Method: Cut a small piece of material. Measure the size with a caliper, and
use the + and - keys on the front of the readout to set in the correct reading.
When the correct reading is set, lock the Readout if desired. This prevents accidentally
re-zeroing of the readout. See Section 3 for more information about how to lock the
readout.
Maintenance
The Digital Readout should be cleaned periodically with compressed air to remove any
dust on the lens and keys. All fasteners should occasionally be checked for tightness.
Do not use any liquid lubricants on the scale assembly, as this may impede the
Encoder's ability to operate properly and attract other contaminants to the scale.