User manual

Accurate Technology Digi Fence Page 13 of 16
Programming
Several functions of this Digital Readout are user programmable. The following
describes how to change the factory defaults to customize your Digital Readout.
To enter Programming Mode:
1. Press and hold the MODE key then momentarily press the 0 key.
2. The LCD will briefly display: pg on (Programming On), then Pr 1, (indicating
Programming Parameter #1).
3. Release the MODE key.
4. The value stored for Pr1 is displayed.
Once in the Programming Mode:
Moving up parameter list - Momentarily press the MODE key to advance through the
Programming Parameter list, first displaying the Programming Parameter number then
the currently programmed value.
Moving down parameter list - Press and hold the ON/OFF key and momentarily press the
MODE key to move backward through the Programming Parameter list.
Increase parameter value - Momentarily press the PLUS (+) key while displaying a
Programming Parameter Value to increase the parameter setting.
Decrease parameter value - Momentarily press the MINUS (-) key while displaying a
Programming Parameter Value to decrease the parameter setting.
Reset parameter value to default setting - Momentarily press the ZERO (0) key while
displaying a Programming Parameter Value to reset it to the factory default value.
Exit programming mode - Press and hold the MODE key. Momentarily depress the 0
key. The LCD will briefly display: pg oFF (Programming Off), and will then return to
normal operation. NOTE: The system will automatically exit programming mode after
60 seconds of no key activity.
Momentarily press Press & Hold