User manual
Accurate Technology Digi Fence Page 10 of 16
Display Resolution
The Digital Readout can be configured to display measurements with different
resolution.
In Normal display mode the resolution is: .01in or .01mm.
In Higher display mode the resolution is: .001in or .01mm
In Lower display mode the resolution is: .1in or .1mm.
Fractions remain the same for all settings: 1/16, 1/32 & 1/64
See Programming Parameter Pr4
Incremental Measurements
To make Incremental measurements, press and hold MODE key for approximately 3
seconds. This switches the Readout to INCremental mode (as shown in the upper left
corner of the LCD). You can now press the ZERO, + or – keys if desired. Any
measurement taken will be an incremental measurement and you will not lose your
original ABSolute position. While in the Incremental measurement mode, the Readout
can be re-zeroed for repeated incremental measurements by pressing the ZERO key.
To recall + and - offsets in Incremental measurement mode, simply press the MODE
key for repeated incremental measurements. Measurement units (in, mm, fraction)
changes are not allowed while in INC mode. To return to the ABS measuring mode,
press the MODE key for 3 seconds.
Lock Mode
The user can “lock-out” the position offset adjustment functions (+, -, 0 keys) to prevent
accidental changes of the current displayed position. To activate the lock mode, press
and hold the ON/OFF key and then momentarily press the MODE key. The word LOCK
will appear in the upper left corner of the LCD, and the +, - and 0 keys will not change
the displayed position.
For a more permanent keypad lock solution, See Programming Parameter Pr3
Reverse Scaling
If you set a zero point on ProScale, moving the scale in one direction will produce
positive readings. Moving the scale past zero in the opposite direction will produce
negative readings. Reverse scaling means changing the orientation of the Encoder so
that positive readings become negative and negative readings become positive. There
are two methods to reverse readings:
1. Slide the Encoder off the scale and re-install the Encoder in the opposite
direction, being careful not to damage the ground fingers inside the Encoder.
2. Change Programming Parameter Pr2