User manual
DigiScale Manual Part # 800-1404-001 Page 32 of 36
NOTES:
1. Offsets are stored when leaving the Incremental mode. Any offsets
will be recalled the next time you switch from Absolute to Incremental
mode.
2. While in Incremental mode, the Units of Measurement cannot be
changed. If the display is reading mm when you enter the INC mode
you cannot change to inches without first returning to the ABS mode.
KEY LOCK
The user can lock-out the operation of the +, DATUM and – key functions to
prevent accidental changes of the currently displayed value.
To lock these keys set Programming Parameter Pr3 =1
See Section 4: Programming, Programming Parameter Pr3
RESOLUTION
The readout can be configured to display measurements in any of three
different resolutions.
1. Low– the resolution is: .1in or .1mm.
2. Normal– the resolution is: .01in or .01mm.
3. High– the resolution is: .001in or .01mm
The display of fractions remains the same for all settings: 1/16, 1/32 & 1/64
See Section 4: Programming, Programming Parameter Pr4
RESTORE READOUT TO FACTORY SETTINGS
Remove the battery. Press and hold IN/MM key while reinstalling the battery.
ERROR CODES
no Enc
If the Encoder is off the Scale, or the Encoder cable is unplugged from
the readout, no Enc will appear on the display. To clear the error:
4. Be sure the encoder is on the scale.
5. Connect the encoder to the readout.
6. Unplug the encoder from the readout for 5 seconds and then
reconnect.