User Manual

5
Figure 3. Installation of the product using a ventilation kit.
RECOMMENDATIONS
Screens (not bundled with the product) shall be attached to the ports of the ventilation kit
to prevent the encroachment of animals that can damage the product or constitute hazard
to the building occupants.
A minimum separation distance of 1 ft is recommended between the supply and exhaust
ducts.
The ducts (B and D) shall be installed without any bends that may impede the flow of air.
The ducts (B and D) shall be insulated to minimize energy losses.
Maintenance
A few activities may be performed during the course of using the product.
The product shall be shut down before any maintenance activity is performed.
Filter
It is recommended to change the filter in the supply vent (A) at least once in three
months depending on the outdoor air quality. The procedure for changing the filter is
presented as follows.
To remove the old filter in the supply vent (A):
o Shut down the product;
o Open the door of the enclosure;
o Locate and hold the heat exchanger (H) firmly with one hand;
o Carefully twist and pull out the supply vent (A) with the other
hand.
NOTE
The heat exchanger (H)
shall not be washed.
NOTE
A filter shall not be
installed in the exhaust
vent (C).
6
Remove the filter in the supply-vent (A) port and replace it with a new
filter.
To reinsert the supply vent (A):
o Clean the vent (A) with a paper towel that is moistened with
isopropyl alcohol;
o Use one hand to hold the heat exchanger (H) and ensure that it
lines up with the port of the supply vent (A) at the top of the
enclosure;
o Use the other hand to insert the supply vent (A) into the port until
it is flush with the top surface of the enclosure.
Duct
A damaged duct can be replaced by using a similar duct with a diameter of 4 in
(~10.2 cm).
The following steps can be followed when changing a duct:
o Shut down the product;
o Loosen the nuts of the clamp of the damaged duct;
o Remove the damaged duct from the port of the appropriate fan;
o Attach a new duct to the port of the appropriate fan;
o Tighten the nuts of the clamp.
Electrical Parts
An electrical part (F, G, I, and J) shall only be replaced if it is faulty. In this situation,
the product shall be shut down and a qualified service technician may be consulted.
Caveat
The product that is described in this manual is designed to ensure the safety of the
customer. Nevertheless, the manufacturer declares that the product is not ready for
use, installation, or operation without electrical certification or field inspection. The
manufacturer explicitly emphasizes that the product is sold “as is” and is not fit for use
in its present state without compliance with applicable regulations and codes. By
purchasing the product, the customer fully and willingly accepts to bear the
responsibility to certify the product, if necessary, before it can be installed or operated
in their jurisdiction. Consequently, the manufacturer is not liable to all forms of
contract or tort, whether direct or indirect without any limitation, if compliance or
enforcement of a lack of compliance is required by the Authority Having Jurisdiction
where the product is purchased and/or installed.
NOTE
Excessive force shall not
be applied when
replacing the filter in the
supply vent (A).
NOTE
The length of a newly
installed duct shall be
5 in (~12.7 cm).
NOTE
Do not apply excessive
force when tightening
the clamp.