User Manual

3
Installation
Please, adhere to the following instructions when installing the product:
The product shall not be installed near hazardous or toxic materials.
The product shall only be installed in horizontal and vertical orientations as
shown in Figure 2(a) and (b), respectively, and shall not be positioned at an
oblique angle.
The product can be sited on a table / floor or mounted on a wall / ceiling.
MINI shall be installed in a space where the indoor air temperature is
within the range of 15ºC27ºC (59.0ºF – 80.F). CLIMATE can be
installed in spaces that are 15ºC 23ºC (59.0ºF – 73.F) in the winter and can
accommodate up to 27ºC (80.6ºF) in the summer. The ideal indoor relative
humidity for the product is from 35% to 50% and shall not exceed 65% at
non-condensing conditions.
The pre-installed supply and exhaust ducts shall be insulated.
The vents and ducts shall NOT be connected to external appliances such
as dryers, fans, furnaces, etc.
The product shall not be powered until the ducts are installed.
Window/Door: A pair of boards with each having one hole or a single
board with two holes shall be fastened to a section of a window/door, and
the ducts shall be inserted into the holes.
Wall/Ceiling: The ducts shall be inserted into two holes that are drilled
through the wall or ceiling that can support the weight.
To power the product, connect the plug of the power adapter to the wall
power. Next, connect the free end of the power adapter to the power
connector port and the product will operate in the Normal mode. The
Boost mode can be activated by pressing the power switch until it latches.
To shut down the product, disconnect the power adapter cord from the
power connector port, and then disconnect the plug of the power adapter
from the wall power.
NOTE
The product shall not be
installed where there is
probable contact with
liquids and/or mists.
NOTE
The product shall be
carefully positioned
such that it may not trip
and cause property
damage or bodily injury.
NOTE
The product shall not be
installed at a location
where there is excessive
heat or exposure to
direct sunlight.
NOTE
Accessories such as
screens, boards, duct
insulation, AC-to-DC
power adapters, self-
tapping screws, and
wall-mounting brackets
are third-party goods
which may not be
provided by the
manufacturer.
NOTE
The product may be
mounted on a wall by
using four wall-
mounting brackets and
four M5 × 10mm self-
tapping screws.
NOTE
The board(s)/wall holes
shall be ≥3 in (~7.6 cm).
NOTE
The Boost mode can be
transitioned to Normal
by simply unlatching the
power switch.
4
Window/Door/Wall/Ceiling
Exhaust duct (MINI)
Supply duct (CLIMATE)
Board(s)
(for windows/doors)
PRODUCT
Supply vent (MINI)
Exhaust vent (CLIMATE)
≤5 ft
Exhaust vent (MINI)
Supply vent (CLIMATE)
(a)
Horizontal orientation.
Window/Door/Wall/Ceiling
Board(s) (for windows/doors)
Exhaust vent (MINI)
Supply vent (CLIMATE)
Supply vent (MINI)
Exhaust vent (CLIMATE)
Supply duct (MINI)
Exhaust duct (CLIMATE)
≤5 ft
≥1 ft
Exhaust duct (MINI)
Supply duct (CLIMATE)
PRODUCT
Supply duct port (MINI)
Exhaust duct port (CLIMATE)
(b)
Vertical orientation.
Figure 2. Schematic depiction of the installation of the product in (a) horizontal (side view) and
(b) vertical (front view) orientations.
Although the supply duct is not visible in Figure 2(a), it may be connected to the board(s) to interface with the outdoors.
Note. Figure 2 is not drawn to scale.
RECOMMENDATIONS
Screens may be attached to the orifices of the board(s), ducts, or wall to prevent
encroaching organisms from damaging the product or constituting hazard to the space
where the product is installed.
There should be a minimum distance of 1 ft between the supply and exhaust ducts.
The ducts should be installed without any bends that may impede the flow of air.
If possible, CLIMATE may be installed in a space where additional makeup supply air, through various
means but not limited to passive inlet vents or other natural and mechanical ventilation options, is available.
Its recommended minimum operating temperature is -5ºC (23ºF).
NOTE
Please comply with all
applicable codes and
regulations when
installing the product.