Safety data sheet

Title
Specifications of Lithium Ion battery (Cylindrical Type) page 3/12
After fully charged, stored for 20days at 60
and rested at room temperature for 1hour.
Discharge time is measured by discharging at
2.5A continuously down to 3.0V end voltage.
more than 30min.
Then next discharge time is measured as
specified in paragraph 4.2 .
more than 40min.
4.6 Full Disharged
State Storage
After fully charged and discharged as specified in
paragraph 4.2 , then store for 20days at 60
and rest at room temperature for 1hour.
Discharging time is measured as specified in
paragraph 4.2 .
more than 50min.
4. Drop
The cell is freely dropped 6 times from a height of
1m onto a flat surface of hard wood.
No electrical change
STANDARD TEST CONDITIONS:
The battery used for the test mentioned above should be new one delivered a week
before at most. The test shall be performed at 20±2(Standard temperature of fifth
grade adopted in JIS Z 8703(Standard Test Conditions)), 65±5(Standard humidity of
twentieth grade adopted in JIS Z 8703(Standard Test Conditions)). It is allowed however
to test at 15~25, 45~85 humidity, as long as there is no big difference in test results.
The battery used for the test without residual capacity indicator. The grade of voltmeter
and ammeter used in the test shall be higher than class 0.5 adopted in JIS C 1102(Electric
Indicator).
5. Design, Construction
A battery unit shall be of the design, construction and physical dimensions shown in the
attached drawing. (Drawing No. NUR18650F-32601)
6. Appearance
There shall be no practical damage such as conspicuous liquid electrolyte leakage, flaw
electrolyte leakage, flaw, rust, dirt, and deformation. The battery must have marketability.
7. Shipment
The battery shall be shipped in 40% charged state.
It is not specified more than 40% capacity remain at SCUD, because of self-discharge.
File No. UR1865-1075
Mobile Energy Company
Lithium-Ion Central Business Unit