Safety data sheet

Material Safety Data Sheet Page 4 of 8
Report No.: DGC160223010GE
This document cannot be reproduced except in full, without prior written approval of ATC. Any unauthorized alteration, forgery or falsification of the content or appearance of
this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the
sample(s) tested and such sample(s) are retained for 30 days only.
Accurate Technology Co., Ltd.
Address: No.345, Baima Block, Guantai Road, Nancheng District, Dongguan, Guangdong, China
Tel: (+86-769) 23301666 Fax: (+86-769) 23301600 Email: dgcs@atc-lab.com Http://www.dgatc-lab.com
Section 5 Fire and Explosion Hazard Data
Flash Point (): N/A
Fire disaster/Explosion risk: Generally, security, no fire and no explosion. While, severe impact and
high fever may cause explode.
Extinguishing agent: Carbon dioxide, dry chemical or foam extinguishers.
Fire extinguishing methods: 1. Fire personnel are required to wear self-contained breathing apparatus
to avoid breathing irritant fumes. Wear protective clothing and equipment to prevent body contact with
electrolyte solution. 2. Rapid evacuation of emergency personnel to leave the fire, quickly cut off the
fire source. 3. To mist cooling the tanks or containers exposed to fire. 4. If the spill has not ignited, water
spray mist to spread the steam and to protect personnel attempting to stop the leak. 5. Large area of the
large fire, use water spray control of unmanned aircraft operated or automatic swinging fire hose.
Fire-fight notes : 1. Move containers as far as possible from the fire scene to department. 2. In
imposing the upper hand to avoid the risk of steam and toxic decomposition products. 3. Tank safety
valve has been sounded, or discoloration due to fire and immediately evacuated.
Section 6 - Accidental Release Measures
The information is of relevance only if the battery is broken and the ingredients are released.
Clean-up methods: 1. Isolate leakage pollution area, access restricted. 2. Recommend emergency
personnel to wear self positive pressure respirator and acid-base proofing overalls. 3. Do not contact
with the leakage directly, if the chemical substances leaked outside of battery, try neutralizing exposed
battery parts with soda ash or sodium bicarbonate until fizzing stops, and using sand or bonding agent to
absorb split acid. 4. Collect residue in a suitable container and place the broken battery in a heavy-duty
plastic bag or other non-metallic container.
Note: 1. Leakage region ventilation. 2. Fight or remove all ignition sources. 3. To prevent leakage of
material into the sewer or confined space. 4. Notify the government health and safety and environmental
protection-related units.