MSDS Information
protect personnel and minimize property damage. Burning liquids may be
extinguished by dilution with water. Do not use direct water stream. May spread
fire.
Protective Equipment For Fire Fighters: Wear positive-pressure self-contained
breathing apparatus (SCBA) and protective fire fighting clothing (Includes fire
fighting helmet, coat, pants, boots and gloves). If protective equipment is not
available or not used, fight fire from a protected location or safe distance.
(See Section 15 for Regulatory Information)
6. ACCIDENTAL RELEASE MEASURES:
Protect People: Isolate Area.
Protect The Environment: Contain liquid to prevent contamination of soil, surface
water or ground water.
Cleanup: For small spills, clean up with absorbent material. Collect material in
suitable and properly labeled open containers. For large spills, dike and pump into
suitable and properly labeled containers.
Handling: Product handled hot may require additional ventilation or local exhaust.
7. Handling & Storage
Storage: Keep containers tightly closed when not in use. Store in stainless steel,
aluminum, plasite 3066 lined containers or 316 stainless steel.
Engineering Controls: Provide general and/or local exhaust ventilation to control
airborne levels below the exposure guidelines.
8. Exposure Controls/Personal Protection
Personal Protective Equipment:
Eye/Face Protection: Use safety glasses. Safety glasses should be sufficient for
most operations; however, for misty operations wear chemical goggles.
Skin Protection: Use gloves impervious to this material.
Respiratory Protection: Atmospheric levels should be maintained below the
exposure guideline. When respiratory protection is required for certain operations,
use an approved air-purifying respirator. In misty atmospheres, use an approved
mist respirator.
Exposure Guideline (s): Propylene glycol: AIHA WEEL is 50 ppm total, 10 mg/m3
aerosol only.