B) Change display to “°F” in lieu of “°C” - After entering the password press the set button 
about 25 times to reach the “CF” display, then press the up or down arrow unit the control 
displays “°F” then press set. Wait 6 seconds and it will be set and the unit will go back to normal 
operation. 
C) High Air Alarm Settings - After entering the password press the set button until you reach 
the “C1” display, then press the up or down arrow unit the control displays your desired setting 
then press set. Wait 6 seconds and it will be set and the unit will go back to normal operation. 
D) Low Air Alarm Settings - After entering the password press the set button until you reach 
the “C2” display, then press the up or down arrow unit the control displays your desired setting 
then press set. Wait 6 seconds and it will be set and the unit will go back to normal operation. 
E) High Product Alarm Settings - After entering the password press the set button until you 
reach the “C3H” display, then press the up or down arrow unit the control displays your desired 
setting then press set. Wait 6 seconds and it will be set and the unit will go back to normal 
operation. 
F) High Product Alarm Settings - After entering the password press the set button until you 
reach the “C3L” display, then press the up or down arrow unit the control displays your desired 
setting then press set. Wait 6 seconds and it will be set and the unit will go back to normal 
operation. 
To change any other parameters in the “Factory Settings” enter the Password and then press the “Set” 
button until the desired Parameter is displayed, then press the up or down arrow until the desired setting is 
displayed then press the “Set” key again. Wait 6 seconds and it will be set and the unit will go back to 
normal operation 
7. Recording the highest and lowest temperature: 
Once turned on and after the C5 delay, the unit will start to record the highest and lowest 
temperature; the record will be refreshed at any time. The values will be kept in memory even after 
the power is turned off. Press the HI/LO button to see the highest temperature recorded. Press it 
again to see the lowest temperature. Holding the HI/LO button for 6 seconds will cause the display to 
flash and a buzzer to sound; the previous highest and lowest temperature readings will be cleared, 
and a new record will begin. (Highest and lowest temperature recording instructions: When 
parameter F4=0, the unit can record highest and lowest temperature at any time. When F4=1,2,3, 
during defrost and delay locking 20 minutes, highest and lowest temperatures are not recorded. 
During air sensor failure, highest and lowest temperatures are not recorded.) 
When set 
C13=00, the temperature in the liquid bottle 
is recorded; 
when
 set C13=01, the temperature of 
the air in the cabinet is recorded. The product temperature corresponds 
to the 
temperature of the 
liquid in the bottle
.
8. Factory default resumption: 
Press and hold the DOWN arrow; at the same time, press the UP arrow and hold for 6 seconds. 
The display will flash and show 888. At this time, all parameters will resume factory default values. 
After 6 seconds, normal operational mode will return. 
9. To check or change the password:  
Enter the inner parameter menu (PAS display) and enter the correct password. After entering the 
inner parameter PAS, press the UP or DOWN arrow to display and change the password, then 
press HI/LO to confirm and store the new password. 