Datasheet

4
Range
Instruction
1. Storage time should be counted from the time of Delivery
2. Test Method & Standard: The battery is charged at ambient temperature (21~25) ,
with a constant current CC/CV at 0.2to charge to 4.2V,and constant voltage
charging to final current to 0.02C,then the battery is discharged with CC 0.2C
to final voltage 2.75V, The discharge time is more than 5 hours.
3. Test
3.1
Conditions:
3.1.1. The testing battery should not exceed one month from users received.
3.1.2. Temperature: 21~25
Relative Humidity: 45%~85%
Atmospheric Pressure: 86kPa~106 kPa
3.2. Testing Instruments:
2.2.1. Volt Meter: In Standard IEC 51/IEC 485 stated 0.5 degree or more .Inner Resistor more than 10KΩ/V
2.2.2 Current Meter: In Standard IEC 51/IEC 485 stated 0.5 degree or more. The total inner Resistor
includes lead wire less than 0.01Ω.
2.2.3 Caliper Scale: Scale defined 0.02mm
2.2.4 Load: Including external circuits, Resistor tolerance is±5%.
2.2.5. Complete Battery Tester
3.3. Inspection method & requirement for battery performance:
Item
Inspection Method
Requirement
1
Weight
Test by electronic scale
Excluding packing
2
Charge Method
Test at ambient
temperature(21~25) ,CC/CV Constant
current charge at 0.2C to 4.2V, and
constant voltage charge to final
current 0.02C
Discharge time:60min.
Battery appearance should not be cracked nor
leaked.
3
Discharge Method
Test at ambient
temperature(21~25) , at constant
current 1C to final voltage2.75V