SP8016-1005 ACCU-STEAM SERVICE MANUAL PAGE 7
REMOVAL AND INSTALLATION
THERMOSTAT
WARNING - ALL THERMOSTATS MUST BE CALIBRATED TO 400 °F, ( +1 )
1.
2.
3.
4.
5.
Note: Units with serial numbers 2611 to 7550 have a type K thermostat and thermocouple.
(red and yellow leads) Serial numbers 7551 and above have a RTD thermostat and probe.
(two red leads). When replacing a thermostat, always use a RTD thermostat and probe.
CALIBRATION POT
K Type Temperature Controller - P/N AT0E-2559-3
This was replaced by the RTD
Controller P/N AT0E-2559-6 &
Thermocouple P/N AT0E-2885-3
Must be used on all older series
griddles with the welded in
thermocouple
RTD Type Temperature Controller - P/N AT0E-2559-6
MUST USE RTD THERMOCOUPLE
P/N AT0E-2885-3
Calibration Pot