Service manual

SP8016-1005 ACCU-STEAM SERVICE MANUAL PAGE 8
RTD THERMOSTAT CALIBRATION



± 
1.
2.
3.


4.

5.
6.
7.

8.
9.
10.

TEMP PROBE
The temperature sensor is screwed into a thermal-well underneath the griddle chamber. It is
isolated from the distilled water of the griddle chamber. It is designed to indicate temperature
by changing the resistance based on temperature to the thermostat. Be careful if you have to
drill out the sensor not to puncture the chamber as it will render the griddle un-repairable.
1.
2.
3.

4.
5.
PROBE LOCATION
UNDERSIDE OF GRIDDLE
RTD TEMPERATURE SENSOR
AT0E-2885-3
REMOVAL AND INSTALLATION