362-13701 AdvNonSAMa 9/13/02 8:20 AM Page a ACCU-CHEK ACCU-CHEK, ADVANTAGE, COMFORT CURVE, CHEK, SOFTCLIX, and CHEMSTRIP are trademarks of a Member of the Roche Group. ® ©2002 Roche Diagnostics. All rights reserved. 093344800-0802 User’s Manual Las instrucciones en español están al revés de este manual. Roche Diagnostics Corporation 9115 Hague Road Indianapolis, IN 46256 www.accu-chek.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page c Throughout manual Table of Contents Welcome .........................................................................3 Where to Find Help.........................................................5 Getting to Know Your Meter and Supplies ....................7 Setting Up Your Meter ..................................................11 Installing or Replacing the Batteries............................11 Turning the Beeper On or Off ....................................
62-13701 AdvNonSAMa 9/13/02 8:20 AM Page 2 Welcome Caring for Your Meter...................................................75 Storage and Handling .................................................75 Cleaning the Meter .....................................................76 Cleaning the Accu-Chek® Softclix® Lancet Device .......77 Accu-Chek® Advantage® Test Strips............................79 Items You Need ..........................................................
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 4 Where to Find Help Accu-ChekSM Customer Care is available to answer your questions 24 hours a day, 365 days a year. We offer assistance in English, Spanish, and many other languages! Call 1-800-858-8072. For valuable information about diabetes management and the complete Accu-Chek® product line, visit www.accu-chek.com.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 6 MEM Button—Press it to review values stored in the meter’s memory. Display Screen—Your blood sugar test result and other information will appear here. On/Off Button—This button has the symbol printed on it. Press it to turn the meter ON or OFF. Test Strip Slot—This is where you insert a test strip. 6 7 Getting to Know Your Meter and Supplies Getting to Know Your Meter and Supplies Throughout manual: all tab sections print solid PMS 287.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 8 Code Key Slot—This is where you insert the code key. Battery Cover—This cover slides off so you can install or change batteries. Code Key—This is used for coding your meter. A new code key comes with every package of test strips. Accu-Chek® Comfort Curve® Test Strip—This is used when testing your blood sugar or glucose control solution. Chek™ Strip—This is used when performing internal electronic checks and quality control checks on your meter.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 10 Setting Up Your Meter Additional Items Throughout manual: -all icons print PMS 287 with white knockout behind the exclamation point. Installing or Replacing the Batteries ® Accu-Chek Comfort Curve® Glucose Control Solution—This solution is used to check the performance of the meter and the test strip. Introduction Your meter comes with two AAA alkaline batteries.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 12 Installing the batteries Follow these steps to install the batteries for your meter. Step Action 1 Slide the battery cover off the back of the meter. 8707004909 3 Action Inside each battery slot is a picture of a battery: AAA This shows you in which direction to install the battery. Match the battery direction with the picture in each slot. Each battery will go in the opposite direction from the other.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 14 Installing the batteries con’t Step 4 Action Hold the end of the clear plastic strip down over the batteries while sliding the battery cover back in place. 8707004909 Turning the Beeper On or Off Introduction Turning the beeper on or off does not affect the test results.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 16 Turning the beeper on or off Follow these steps to turn the beeper on or off. Step Action 1 Press the On/Off turn on the meter. 2 Press the On/Off and MEM buttons at the same time until Set appears on the screen, then release both buttons. Step Press the On/Off button to switch the beeper on or off. 4 Press the On/Off and MEM buttons at the same time to exit and save your setting for the beeper. If you see the word On, then the beeper is on.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 18 Setting the Time and Date Step Introduction The time and date should be set prior to testing if you plan to download the results into software or if you or your healthcare professional plan to review your memory to check when a test was done. 2 Action Press the On/Off and MEM buttons at the same time until Set appears, then release both buttons. You will see a screen like the one below. Either the word On or the word OFF will be flashing.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 20 Setting the time and date con’t Step Action Step Action 3 Now press the MEM button. 6 Press and release the On/Off button until the correct minutes are displayed. 7 Now press the MEM button. The hour digit and AM will flash. 5 Press and release the On/Off button until the correct hour is displayed. AM will change to PM automatically when scrolling through the hours. Press the MEM button so that the minute digits start flashing.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 22 Setting the time and date con’t Step Action 10 Press and release the On/Off button until the correct day is displayed. 11 Now press the MEM button. Coding Your Meter Introduction Before you use your meter for the first time and every time you open a new box of test strips, you need to set the meter to “match” the strips. This is called coding or calibration. The On or OFF screen will reappear.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 24 You will need to insert a new code key: • Whenever you open a new box of strips. • Whenever either one of these displays appears: Step Action 2 Find the new code key that came in the box of test strips. Hold the end of the code key that has the ridges. With the black square facing the meter, insert the code key. It will slide easily into the meter and will snap in place. Do not force it into the meter.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 26 Coding Your Meter con’t Step 3 Glucose Control Testing Action Press the On/Off turn on the meter. button to A 3-digit code number appears. This number should match the code number on your vial of test strips. If it does not, repeat steps 1-3. Why is Glucose Control Testing Important? Glucose control testing is used to check the performance of the meter and test strip. Glucose control testing is done using glucose control solutions instead of blood.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 28 Items You Need • Accu-Chek® Advantage® Meter • Accu-Chek® Comfort Curve® Test Strips • Accu-Chek® Comfort Curve® Glucose Control Solutions • Chek™ Strip You will find the acceptable glucose control range printed on the vial of the test strips. How to Run a Glucose Control Test ® ® The Accu-Chek Advantage Kit is packaged with one level of glucose control solution. When purchased at a store, glucose control solutions are packaged with two levels per box.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 30 Glucose Control Testing con’t Step Action When the Chek™ Strip is inserted, the meter will turn on automatically. Step 2 Action Remove the Chek™ Strip when you see the OK screen. When the Chek™ Strip is removed, you will see L1, a flashing test strip symbol, and ✔ on the screen. ▲ Example code number The code number must match the code number on the vial of test strips.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 32 Glucose Control Testing con’t Step 4 Action Insert a test strip (yellow window facing up) into the test strip slot. The test strip symbol will stop flashing and a blood drop symbol will appear. 5 Step Action 6 Hold the control bottle horizontally and gently squeeze the bottle to form a small drop on the tip of the bottle. 7 Bring the drop to the curved edge of the strip.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 34 Glucose Control Testing con’t Step 8 9 Action When the control solution is applied to the strip, a box symbol will move around the display screen until the measurement is completed. Replace the cap tightly on the control solution. 10 The control result will be displayed. Step Action If the control result is within the acceptable range, the result and the OK screen will alternate.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 36 Glucose Control Testing con’t Step Action 11 Remove the test strip from the meter and discard it. When the test strip is removed, you will see the L2, a flashing test strip symbol, and ✔ on the screen. Step Action 12 When you are finished testing, press the On/Off button to turn the meter off. Your meter is now ready for a Level 2 glucose control test. The Level 2 test is optional.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 38 Blood Sugar Testing Items You Need • Check the expiration date of the test strips. If the strips have expired, dispose of them promptly. • Control solution is only good for 3 months after opening. If it has been open longer than 3 months, dispose of the solution. • Make sure the cap was placed tightly on the vial of test strips and control solutions. The test strips and control solutions can be damaged when they are not capped and stored properly.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 40 Inserting a Test Strip Introduction Insert a test strip into the Accu-Chek® Advantage® Meter prior to testing. If this is your first time to test, you may want to read all of the instructions thoroughly before removing the test strip. Once you have removed the strip from the vial, you have 3 minutes to complete testing. Inserting a test strip Follow these steps to insert a test strip into the meter. Step Action 1 Remove a new test strip from the vial.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 42 Step 3 Action The meter will turn on automatically when the test strip is inserted. Step 4 Action When the flashing blood drop symbol appears, the meter is ready to perform a test. A 3-digit code number appears. This number must match the code number on the vial of test strips. ▲ Example code number. 42 To continue, follow the instructions for using the Accu-Chek® Softclix® Lancet Device to obtain a drop of blood.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 44 Using the Accu-Chek® Softclix® Lancet Device The Accu-Chek® Softclix® Lancet Device uses lancets to obtain a drop of blood from your fingertip. You can adjust the penetration depth by using the Comfort Dial™. cap with Comfort Dial depth selection lancet holder protective cap Follow these steps to use your AccuChek® Softclix® Lancet Device to get a drop of blood. Step Action 1 Pull the cap, with the Comfort Dial, off the lancet device.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 46 Step Action 3 Twist the round protective cap on the lancet several times and pull gently to remove it. 4 Put the cap back onto the lancet device. The cap fits when the notch on the cap is aligned with the center of the semicircular cutout. It should easily snap into place. 46 Step 5 Action To adjust the depth setting, turn the cap. You will see numbers and dots in the semicircular cutout area. Dots represent half settings.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 48 Step 6 Action Press the plunger on the end of the lancet device all the way down until you hear a click. You will also see a yellow dot appear in the center of the clear release button. Step Action 7 Wash your hands in warm soapy water and dry thoroughly. 8 Let your arm hang down at your side briefly to increase blood flow to the fingertip. 9 Grasp your finger near the area to be pricked and gently massage for three seconds.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 50 Step Action 10 Press the tip of the Accu-Chek® Softclix® Lancet Device firmly against your fingertip. How to Run a Blood Sugar Test with an Accu-Chek® Comfort Curve® Test Strip Introduction The following instructions are for the Accu-Chek® Comfort Curve® Test Strips. Accu-Chek® Comfort Curve® Test Strip—has a curved edge. 11 Press the release button, then gently squeeze your finger until you get a small drop of blood.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 52 Follow these steps to apply a drop of blood to an Accu-Chek® Comfort Curve® Test Strip. Step 1 Allow the blood to be drawn in as you keep your finger on the curved edge of the test strip. Do not try to place the blood drop directly on top of the yellow window. Action Touch and hold the drop of blood to the curved edge of the test strip where you see the yellow window. The blood will be drawn into the strip automatically.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 54 Step Action If you see any yellow color in the window after you have applied the drop of blood, a second drop of blood may be applied within 15 seconds. Step Action Once the blood sugar result is displayed, it will be automatically recorded in the meter’s memory. If more than 15 seconds have passed, retest with a new strip.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 56 Disposing of Used Lancets Step 4 Action Remove the test strip from the meter. Introduction When the test strip is removed, the test strip symbol will start to flash on the screen. Dispose of the used test strip and used lancet in a puncture-proof container with a lid. You may use a disposal container that was designed for such items. Ask your healthcare professional for disposal details. To avoid infection, use a new lancet each time you perform a test.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 58 Understanding Your Blood Sugar Test Results Step 2 Action Point the exposed end of the Accu-Chek® Softclix® Lancet Device away from you and toward the disposal container opening. What’s Normal? The normal fasting adult blood sugar range for a person without diabetes is 70-109 mg/dL1. One or two hours after meals, normal blood sugar levels should be less than 140 mg/dL2. Your doctor will determine the range that is appropriate for you.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 60 your blood sugar result seems unusually high or low, Follow the advice of your doctor before you change your therapy. AND...
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 62 IF... you get a low blood sugar result or LO is displayed, your blood sugar result is above 240 mg/dL, AND... this has occurred for several days, THEN... AND... contact your doctor and check your urine ketone levels with Roche Diagnostics’ Chemstrip® K or Chemstrip® uGK Test Strips. symptoms are absent, THEN... run a glucose control check with your glucose control solutions and a new test strip. See Glucose Control Testing (page 27).
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 64 Blood Sugar Testing IF... IF... HI is displayed, HI is displayed, AND... AND... you also experience symptoms of high blood sugar: fatigue, increased appetite or thirst, frequent urination, blurred vision, headache, or achiness, this does not confirm the way you feel, THEN... contact your doctor immediately. THEN... check that test strip has not expired or been damaged, then retest.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 66 IF... mg/dL and error are displayed, mg/dL and error are displayed, AND... AND... you also experience symptoms of high blood sugar: fatigue, increased appetite or thirst, frequent urination, blurred vision, headache, or achiness, symptoms are absent, THEN... run a glucose control check with your glucose control solutions and a new test strip. See Glucose Control Testing (page 27).
2-13701 AdvNonSAMa 9/13/02 8:20 AM Page 68 Memory Automatic Results Storage The Accu-Chek® Advantage® Meter automatically stores 100 results. You can review them in order from the most recent to the oldest. If you have set the time/date feature, the times and dates of the results are also displayed. The memory is full when 100 results have been entered, and MEM flashes on the display screen when the meter is turned on. Results cannot be erased from the meter’s memory.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 70 How to Review Results Stored in Memory Step Reviewing Stored Results Follow these steps to review results stored in memory. Step 1 Action 2 Action When the test strip symbol flashes, press and hold the MEM button. Press the On/Off button to turn the meter on. A 3-digit code number appears. This number must match the code number on your vial of test strips. ▲ Example code number. 70 71 Memory The memory order number (1-100) is displayed.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 72 Step Action Step 3 Release the MEM button. The result, date, and time are displayed. 5 Action Press the On/Off button to turn the meter off at any time. ▲ Example result Press the MEM button and the next memory number will be displayed. Release the MEM button and the results will appear. Press and release the MEM button to see the remaining stored results. The stored results are displayed from the newest to the oldest.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 74 How to Transfer Stored Data ® Caring for Your Meter ® The Accu-Chek Advantage Meter allows you to transfer all the data in its memory to your home computer or to your heathcare professional’s office computer. If you would like to transfer the data from your meter to your home computer, call 1-800-428-5076 to purchase Accu-Chek® Compass™ Software and the Accu-Chek® Advantage Cable.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 76 Cleaning the Meter Cleaning the Accu-Chek® Softclix® Lancet Device Clean your meter as needed using one of the following: • 70% isopropyl alcohol • a solution of mild dish washing liquid and clean water • 10% household bleach solution (1 part bleach in 9 parts water) made fresh To clean the Accu-Chek® Softclix® Lancet Device, use a soft cloth dampened with mild dish washing liquid. • DO NOT place the entire device under water.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 78 The following instructions are for Accu-Chek® Advantage® Test Strips only. If your test strips have a curved edge, you need to follow the instructions for the Accu-Chek® Comfort Curve® Test Strips. The instructions for each type of strip are different.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 80 • Accu-Chek® Advantage® Meter • Accu-Chek® Advantage® Test Strips • Accu-Chek® Advantage® Glucose Control Solutions • Chek™ Strip When purchased at a store, glucose control solutions are packaged with two levels per box. Only one level of control solution is required for glucose control testing.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 82 Step Action ™ When the Chek Strip is inserted, the meter will turn on automatically. Step 2 Action Remove the Chek™ Strip when you see the OK screen. When the Chek™ Strip is removed, you will see L1, a flashing test strip symbol and a ✔ on the screen. ▲ Example code number The code number must match the code number on the vial of test strips. The number will disappear and you will see OK and ✔ on the display screen.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 84 Step 4 Action Insert a test strip (yellow window facing up) into the test strip slot. The test strip symbol will stop flashing and a blood drop symbol will appear. 5 Step Action 6 Hold the control bottle horizontally and gently squeeze the bottle to form a small drop on the tip of the bottle. 7 Apply the drop to the center of the yellow window of the test strip. Let only the drop, and not the tip of the bottle, touch the yellow window.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 86 Step 8 9 Action When control solution is applied to the strip, a box symbol will move around the display screen until the measurement is completed. Replace the cap tightly on the control solution. 10 The control result will be displayed. Step Action If the control result is within the acceptable range, the result and the OK screen will alternate.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 88 Step Action 11 Remove the test strip from the meter and discard it. When the test strip is removed, you will see the L2 screen. You will also see a flashing test strip symbol and a ✔. Step Action The Level 2 test is optional. If you have a bottle of Level 2 control solution that you would like to use, you may repeat the steps starting with step 3. You will need to use the Level 2 control solution in place of the Level 1 solution.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 90 How to Run a Blood Sugar Test with an Accu-Chek® Advantage® Test Strip Step Running a Blood Sugar Test with an Accu-Chek® Advantage® Test Strip Follow these steps to run a blood sugar test with an Accu-Chek® Advantage® Test Strip. Step 1 Action Look at the yellow window on the test strip. If you have enough blood on the strip, you will not see any yellow left. The yellow window will be completely filled with blood.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 92 Step Action If you see any yellow color in the window after you have applied the drop of blood, a second drop of blood may be applied within 15 seconds. Step Action Once the blood sugar result is displayed, it will be automatically recorded in the meter’s memory. If more than 15 seconds have passed, retest with a new strip.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 94 Running a Blood Sugar Test with an Accu-Chek® Advantage® Test Strip con’t Step 4 Action Remove the test strip from the meter. When the test strip is removed, the test strip symbol will start to flash on the screen. If you are finished testing, press the On/Off button to turn the meter off. 6 Follow the instructions for disposing used lancets found on page 57. 7 See Understanding Your Blood Sugar Test Results (page 59). 94 Q. How do I code my meter? A.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 96 Troubleshooting Guide The following are display and error messages that may appear on the meter. If you are unable to resolve a concern, please call Accu-ChekSM Customer Care at 1-800-858-8072, 24 hours a day, 365 days a year. Do not make treatment decisions based on an error message.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 98 IF... IF... LO is displayed. HI is displayed. REASON REASON The blood sugar result is below the measuring range of your test strips. The blood sugar result is above the measuring range of your test strips. ACTION ACTION See Understanding Your Blood Sugar Test Results, See Understanding Your Blood Sugar Test Results (pages 59-67). (pages 59-67).
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 100 IF... mg/dL and error are displayed. the following screen is displayed. REASON REASON The blood sugar result may be extremely high and above the system’s reading range. This display check appears when you press the MEM button while you turn the meter on. You can also press and hold the On/Off button to view this display. ACTION ACTION Immediately see Understanding Your Blood Sugar Test Results (pages 59-67).
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 102 IF... the following screen is displayed. the following screen is displayed. REASON REASON The meter needs to be coded or the code key is not inserted completely. The code key is faulty or was removed while the meter was on. ACTION Turn the meter off and correctly insert the code key. See Coding Your Meter (page 23). ACTION Turn the meter off and reinsert the code key.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 104 IF... the following screen is displayed. IF... the following screen is displayed. Blue circle placed over screen captures prints PMS 287. ▲ Example code number ▲ Example result REASON The temperature is outside the operating range of the test strips (57°-104°F or 14°-40°C). The meter is turned on and the memory is full with 100 values. MEM flashes. ACTION ACTION The result you have obtained may not be accurate.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 106 IF... the following screen is displayed. REASON REASON The battery power is low. The system will allow only a few additional tests to be performed. The battery is depleted. The system will not allow a test to be performed. Only memory results can be recalled. ACTION ACTION Change the batteries soon. You will need two AAA alkaline batteries of the same brand. Results stored in memory will not be lost when you replace the batteries.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 108 IF... the following screen is displayed. IF... the following screen is displayed. REASON REASON The meter has failed its internal system check. The test strip may be damaged or the test was not performed correctly. ACTION ACTION ™ Remove the Chek Strip. Turn the meter off and repeat the glucose control check. See Glucose Control Testing (page 27). If this error display still appears, testing cannot take place.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 110 IF... the following screen is displayed. IF... the following screen is displayed. REASON REASON The batteries may have been removed or replaced. A loss of all results in the meter’s memory has occurred. ACTION ACTION If this symbol disappears after approximately 30 seconds, you may continue with a test. If this symbol remains after 30 seconds, call Accu-ChekSM Customer Care at 1-800-858-8072. Turn the meter off, then on again.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 112 Other Information Product Limitations Please read the information packaged with your test strips regarding up-to-date product specifications and limitations. Product Specifications System Operating Conditions Refer to your test strip package insert The meter has failed its series of electronic checks. Meter Storage Conditions -13°–158°F (-25°–70°C) ACTION Humidity Less than 95% Atmospheric Pressure > 53.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 114 Power Supply 2 oz. (60 gm) without batteries Product Safety Information Explanation of symbols Two 1.5-volt alkaline (AAA) batteries (type LR03) = Caution - important safety information. These batteries are available in most retail outlets. = Attention - important information.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 116 Warranty Additional Supplies Test Strips Accu-Chek® Comfort Curve® Test Strips Cat. Nos. 2030365, 2030373, 2030381, 2030420, 3000133, 3000141, 3000150 Accu-Chek® Advantage® Test Strips Cat. Nos. 336, 338, 551, 553, 966, 787 Glucose Controls Accu-Chek® Comfort Curve® Glucose Control Solutions Cat. Nos. 2030390, 2030403, 2030411 Accu-Chek® Advantage® Glucose Control Solutions Cat. Nos. 552, 906, 986, 989 Lancets Accu-Chek® Softclix® Lancet Device Cat. No.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 118 Some states do not allow limitations on how long an implied warranty will last or the exclusion of incidental or consequential damages, so the above elimination and exclusion may not apply to you. This warranty gives you specific legal rights, which vary from state to state. Non-Warranty Service Warranty Roche Diagnostics’ Non-Warranty Service Warranty applies to meters where the above warranty has not become effective, has become inapplicable, or has expired.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 120 The Accu-Chek® Advantage® System (meter, including the code key, and test strips) and its use is protected by US Patent Nos. 5,508,171; 5,053,199; 5,288,636; 5,405,511; 5,366,609; 5,762,770 (applies only to Advantage® Test Strips); Re. 36,268 (applies to the Accu-Chek® Advantage® and Complete™ Systems when used with Accu-Chek® Comfort Curve® Test Strips); and 5,352,351.
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 122 Index Accu-Chek Advantage Test Strips . . . . . . . . . . . .79 Accu-Chek Comfort Curve Test Strips . . . . . . .9, 51 Accu-Chek Softclix Lancet Device . . . . . .10, 44, 77 Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 Battery Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 Battery Installation . . . . . . . . . . . . . . . . . . . . . . . .11 Battery Symbol . . . . . . . . . . . . . . . . . . . . . . . . . .
362-13701 AdvNonSAMa 9/13/02 8:20 AM Page 124 Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . .113 LO Display . . . . . . . . . . . . . . . . . . . . . . . .61, 62, 98 MEM Button . . . . . . . . . . . . . . . . . . . . . . . .7, 71, 72 Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .69 ON/OFF Button . . . . . . . . . . . . . . . . . . . . . . . . . . .7 References . . . . . . . . . . . . . . . . . . . . . . . . . . . .121 Specifications . . . . . . . . . . . . . . .