System information
Command Line Interface
4-108
efm interleave
This command sets the interleave parameters for the selected VDSL port.
Syntax 
efm interleave [downstream M value] [upstream M value]  
[downstream I value] [upstream I value]
no efm interleave 
• M value – M is the interleaving depth index; Range: 0-64
• I value – I is the interleaving block length; Range: 4 or 8
Default Setting 
• M – The interleaving depth index.
Upstream default value: 8, Downstream default value: 16
• I – The interleaving block length.
Upstream default value: 8, Downstream default value: 8
Command Mode 
Interface Configuration
Command Usage 
Interleaving improves Reed Solomon error correction when there is pulse 
noise. A greater degree of interleaving will provide more protection against 
pulse noise but will increase transmission delay and reduce the effective 
bandwidth of the link. The degree of interleaving can be increased by 
increasing M or I.
Example
The following example configures VDSL port 1 with –
• M - downstream value: 16, Upstream value: 8
•  I - downstream value: 8, Upstream value: 8
Related Commands 
efm noise-margin (4-109)
show controllers efm status (4-116)
Console#config
Console(config)#interface ethernet 1/1
Console(config-if)#efm interleave 16 8 8 8
Console(config-if)#end
Console#show controllers efm status link Ethernet 1/1
Interface Link SNR (dB)  RS Errs Interleaver
  DS1 DS2 US1 US2  DS.M DS.I US.M US.I PBO
------------- ---- -------------------- -------- ------------------- 
---
Ethernet 1/1 Up 43.0 35.0 45.0 43.0 0 16 8 8  8 on
Console#