System information
VDSL Commands
4-105
4.  The maximum distances for VDSL links using the recommended profiles 
are: 
5.  Type-1 26 AWG (100 ohm)/0.4 mm, or Type-2 24 AWG (100 ohm)/0.5 mm 
cable may be installed to achieve the maximum distance, however, typically, 
24 AWG (100 ohm)/0.5 mm wire is better than 26 AWG (100 ohm )/0.4 mm 
wire. Note that the distance may be limited by factors such as how the cable 
is bundled, and the interference and noise on the link.
6.  Public profiles conform to specific standards such as ANSI or ETSI. Private 
profiles do not conform to these standards.
Example 
Related Commands 
efm profile (4-105)
efm profile
Use this command to assign profiles for speed to a specific VDSL port on the switch.
Syntax 
efm profile profile name
profile name - Name of the profile. 
Default Setting 
None
Command Mode 
Interface Configuration
Command Usage 
Assigns a profile to a specific VDSL port. For details of the these profiles see 
the table under Command Usage for efm profile global.
Example
The following example shows EFM profile S1-16-16 assigned to VDSL port 1.
Upstream Downstream Mode Max. Range
16 Mbps 16 Mbps Symetric 600m (1970 ft)
11 Mbps 34 Mbps Asymetric 610m (2000 ft)
Console#config
Console(config)#efm profile global S1-16-16 
Console(config)#
Console#config
Console(config)#interface ethernet 1/1
Console(config-if)#efm profile S1-16-16
Console(config-if)#