System information

VDSL Commands
4-105
4. The maximum distances for VDSL links using the recommended profiles
are:
5. Type-1 26 AWG (100 ohm)/0.4 mm, or Type-2 24 AWG (100 ohm)/0.5 mm
cable may be installed to achieve the maximum distance, however, typically,
24 AWG (100 ohm)/0.5 mm wire is better than 26 AWG (100 ohm )/0.4 mm
wire. Note that the distance may be limited by factors such as how the cable
is bundled, and the interference and noise on the link.
6. Public profiles conform to specific standards such as ANSI or ETSI. Private
profiles do not conform to these standards.
Example
Related Commands
efm profile (4-105)
efm profile
Use this command to assign profiles for speed to a specific VDSL port on the switch.
Syntax
efm profile profile name
profile name - Name of the profile.
Default Setting
None
Command Mode
Interface Configuration
Command Usage
Assigns a profile to a specific VDSL port. For details of the these profiles see
the table under Command Usage for efm profile global.
Example
The following example shows EFM profile S1-16-16 assigned to VDSL port 1.
Upstream Downstream Mode Max. Range
16 Mbps 16 Mbps Symetric 600m (1970 ft)
11 Mbps 34 Mbps Asymetric 610m (2000 ft)
Console#config
Console(config)#efm profile global S1-16-16
Console(config)#
Console#config
Console(config)#interface ethernet 1/1
Console(config-if)#efm profile S1-16-16
Console(config-if)#