VDSL Switch-VS2512A VDSL Splitter-VM2524 VDSL Splitter-VM2548 Installation Guide
Installation Guide VDSL Switch-VS2512A VDSL Switch supporting 12 VDSL Lines, with 1 Slot for Optional Gigabit Uplink, 10/100BASE-TX, or 100BASE-FX Modules VDSL Splitter-VM2524 VDSL Splitter supporting 24 VDSL Lines VDSL Splitter-VM2548 VDSL Splitter supporting 48 VDSL Lines
Copyright © 2002 by Accton Technology Corporation. All rights reserved. No part of this document may be copied or reproduced in any form or by any means without the prior written consent of Accton Technology Corporation. Accton makes no warranties with respect to this documentation and disclaims any implied warranties of merchantability, quality, or fitness for any particular purpose. The information in this document is subject to change without notice.
Accton Technology Corporation Limited Warranty: Accton warrants all its products to be free of manufacturing defects in workmanship and materials, under normal use and service, for the applicable warranty term. All Accton products carry a standard 90-day limited warranty from the date of purchase from Accton or its Authorized Reseller.
Limited Warranty WARRANTIES EXCLUSIVE: IF AN ACCTON PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE, CUSTOMER'S SOLE REMEDY SHALL BE REPAIR OR REPLACEMENT OF THE PRODUCT IN QUESTION, AT ACCTON’S OPTION. THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER. WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, EITHER IN FACT OR BY OPERATION OF LAW, STATUTORY OR OTHERWISE, INCLUDING WARRANTIES OR CONDITIONS OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
Compliances FCC - Class A This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause interference to radio communications. It has been tested and found to comply with the limits for a Class A computing device pursuant to Subpart B of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment.
CE Mark Declaration of Conformance for EMI and Safety (EEC) This information technology equipment complies with the requirements of the Council Directive 89/336/EEC on the Approximation of the laws of the Member States relating to Electromagnetic Compatibility and 73/23/EEC for electrical equipment used within certain voltage limits and the Amendment Directive 93/68/EEC.
Safety Compliance Warning: Fiber Optic Port Safety CLASS I LASER DEVICE When using a fiber optic port, never look at the transmit laser while it is powered on. Also, never look directly at the fiber TX port and fiber cable ends when they are powered on. Avertissment: Ports pour fibres optiques - sécurité sur le plan optique DISPOSITIF LASER DE CLASSE I Ne regardez jamais le laser tant qu'il est sous tension.
Wichtige Sicherheitshinweise (Germany) 1. Bitte lesen Sie diese Hinweise sorgfältig durch. 2. Heben Sie diese Anleitung für den späteren Gebrauch auf. 3. Vor jedem Reinigen ist das Gerät vom Stromnetz zu trennen. Verwenden Sie keine Flüssigoder Aerosolreiniger. Am besten eignet sich ein angefeuchtetes Tuch zur Reinigung. 4. Die Netzanschlu ßsteckdose soll nahe dem Gerät angebracht und leicht zugänglich sein. 5. Das Gerät ist vor Feuchtigkeit zu schützen. 6.
Contents Chapter 1: About the VDSL Switch-VS2512A Overview VDSL Technology Switch Architecture Management Options Description of Hardware VDSL Switch-VS2512A VDSL Splitter-VM2524 and VDSL Splitter-VM2548 Ethernet-over-VDSL CPE Status LEDs Optional Media Extender Modules Power Supply Receptacle Key Features 1-1 1-1 1-2 1-3 1-3 1-4 1-4 1-5 1-6 1-7 1-8 1-11 1-12 Chapter 2: Network Planning Introduction to Switching Sample Applications Internet Connections Remote Connections with Fiber Cable Making VLAN Conne
Contents Appendix A: Troubleshooting Diagnosing Switch Indicators Power and Cooling Problems Installation In-Band Access A-1 A-1 A-1 A-2 A-2 Appendix B: Cables Specifications.
Chapter 1: About the VDSL Switch-VS2512A Overview Accton’s Ethernet-over-VDSL system consists of end-user CPEs (Customer Premise Equipment) connected to a VDSL switch and splitter by standard telephone cable. The VDSL connection delivers an Ethernet data link rated up to 15 Mbps symmetric (full duplex), while simultaneously supporting standard telephone services.
About the VDSL Switch-VS2512A VDSL Technology VDSL (Very High Bit-Rate Digital Subscriber Line) is at the high-end of all the DSL technologies, offering the best combination of fiber optics and copper to provide high-speed broadband Internet access. VDSL’s primary application is in providing a broadband data service to multi-tenant residential or commercial buildings.
Overview Switch Architecture The VDSL Switch-VS2512A employs a wire-speed, non-blocking switching fabric. This permits simultaneous wire-speed transport of multiple packets at low latency on all ports. This switch also features full-duplex capability on all ports, which effectively doubles the bandwidth of each connection. Management Options This switch contains a comprehensive array of LEDs for “at-a-glance” monitoring of network and port status.
About the VDSL Switch-VS2512A Traffic Priority This switch provides Quality of Service (QoS) by prioritizing each packet based on the required level of service, using four distinct categories with Weighted Round Robin Queuing. It uses IEEE 802.1p and 802.1Q tags to prioritize incoming traffic based on input from the end-station application. These functions can be used to provide independent priorities for delay-sensitive data and best-effort data.
Description of Hardware The switch also includes key system and port indicators that simplify installation and network troubleshooting. The front panel has LEDs for Ethernet link status/activity and VDSL link status, as well as system status indicators. The following figure shows the components of the VDSL Switch.
About the VDSL Switch-VS2512A The following figures shows the components of the VDSL Splitter-VM2524 and VDSL Splitter-VM2548. Line VDSL Splitter -VM2524 VM2524 VDSL Line Connector (to end users) PBX PBX/MDF Connector (to POTS provider) VDSL Switch VDSL Line Connector (to switch) Figure 1-3.
Description of Hardware Status LEDs The LEDs, which are located on the VS2512A front panel for easy viewing, are shown below and described in the following table. Ethernet VDSL 1 Master On Off 2 3 4 5 6 7 8 9 1 10 11 12 Activity Activity Link Link/Speed 2 3 4 Stacking Power Diag Figure 1-5.
About the VDSL Switch-VS2512A Optional Media Extender Modules Optional 1000BASE-SX Module (VM2512A-1SX-SC-M) 1000BASE-SX Multimode Module TX RX VM2512A-1SX-SC-M Figure 1-6. Single-Port 1000BASE-SX Gigabit Module Using multimode fiber optic cable, the 1000BASE-SX port can be connected to a remote site up to 550 m (1805 ft) away. The 1000BASE-SX Gigabit module operates at 1 Gbps, with support for full-duplex mode and flow control.
Description of Hardware 1000BASE-SX GBIC transceivers provide one short-wavelength (850 nm) Gigabit port that can be used for a high-speed backbone or server connection. This port can be connected to a site up to 220 m (722 ft) away with 62.5/125 micron multimode fiber cable, or up to 500 m (1641 ft) with 50/125 micron multimode fiber cable. 1000BASE-LX GBIC transceivers provide one long-wavelength (1300 nm) Gigabit port that can be used for a high-speed backbone or server connection.
About the VDSL Switch-VS2512A Optional 10/100BASE-TX Module (VM2512A-4TX) 10/100BASE-TX Module VM2512A-4TX Figure 1-11. 4-Port 10/100BASE-TX Module Using Category 3, 4, or 5 twisted-pair cable for 10 Mbps links or Category 5 twisted-pair cable for 100 Mbps links, you can connect to another device up to 100 m (328 ft) away. The 10/100BASE-TX module operates at 10, 100 Mbps, full and half duplex, and supports auto-negotiation of speed and flow control.
Description of Hardware Optional 100BASE-FX Module (VM2512A-4FX-MTRJ-S) 100BASE-FX Singlemode Module VM2512A-4FX-MTRJ-S Figure 1-14. 4-Port 100BASE-FX Single-mode Module Using 9/125 micron single-mode fiber cable, the 100BASE-FX ports can be connected to a remote site up to 20 km (12.43 miles) away. The 100BASE-FX module operates at 100 Mbps, with support for full-duplex mode and flow control.
About the VDSL Switch-VS2512A Key Features VDSL features (CPE side) include: • High-speed Internet access over existing phone lines • VDSL connection provides the following rate/range options: Rate Mode Max.
Key Features • Provides Store-and-Forward switching for intra-VLAN traffic • Supports wire-speed Layer 2 switching • Supports flow control, using back pressure for half duplex and IEEE 802.
About the VDSL Switch-VS2512A 1-14
Chapter 2: Network Planning Introduction to Switching A network switch allows simultaneous transmission of multiple packets via non-crossbar switching. This means that it can partition a network more efficiently than bridges or routers. The switch has, therefore, been recognized as one of the most important building blocks for today’s networking technology.
Network Planning Internet Connections The figure below shows a VDSL Switch-VS2512A and VDSL Splitter-VM2524 providing a broadband data service to a multi-tenant residential or commercial building. In this implementation, fiber optic cable carries data from a telephone company’s central office to the building; then the installed telephone copper wires take the data and deliver it to individual units within that building.
Sample Applications Making VLAN Connections VLANs can be based on port groups, or each data frame can be explicitly tagged to identify the VLAN group to which it belongs. When using port-based VLANs, ports can be assigned to one or more groups. Port-based VLANs are suitable for small networks. A single switch can be easily configured to support several VLAN groups for various organizational entities (such as Finance and Marketing).
Network Planning Application Notes 1. For network applications that require routing between dissimilar network types, you can attach the VDSL switch directly to a router. 2. The multimode fiber modules are fitted with SC connectors, but you can attach an ST plug to the switch using Accton’s optional SC-to-ST plug converter (Part Number: ST5002, for 62.5/125 micron cable only).
Chapter 3: Installing the VDSL Switch and Splitter Preparing the Site In multi-tenant buildings, phone lines coming from the service provider are generally attached to a PBX or MDF distribution box in the basement. These lines run from the PBX to a punch-down block, and then up to the POTS terminals for individual users. The following figure displays the normal wiring before installing the VDSL switch and splitter.
Installing the VDSL Switch and Splitter Package Contents VDSL Switch-VS2512A • VDSL Switch-VS2512A • Four adhesive foot pads • Bracket Mounting Kit containing two brackets and four screws for attaching the brackets to the switch • One Power Cord—either US, Continental Europe or UK • • • • RS-232 console cable One FireWire Stack Cable This Installation Guide Management Guide VDSL Splitter-VM2524/2548 • VDSL Splitter-VM2524 or VDSL Splitter-VM2548 • Four adhesive foot pads • Bracket Mounting Kit containing
Mounting • Power requirements: 100 to 240 VAC (± 10%) at 50 to 60 Hz (± 3Hz). The switch and splitter power supplies automatically adjust to the input voltage level. Make sure that a properly grounded power outlet is within 2.5 m (8 ft) of the switch and splitter. • The switch and splitter should be located in a cool dry place, with at least 10 cm (4 in.) of space on the sides for ventilation.
Installing the VDSL Switch and Splitter 2. Mount the device in the rack, using four rack-mounting screws (not provided). Expans ion Mo dule Stack ing Up Down Mast er 1 On Activity Off Link 2 3 4 VDS 5 6 L 7 8 9 10 11 12 Ethe Activ Link/ ity Spee d 1 2 rnet 3 4 Stack ing Powe Diag VDS r Rese L Swi t Cons tch -VS 251 2A ole VS25 12A 100-2 40V ~ 50-60 Hz 1A Figure 3-3. Installing the Switch in a Rack 3.
Mounting 3. If installing a single switch only, go to “Powering On the Switch” at the end of this chapter. 4. If installing multiple switches, attach four adhesive feet to each one. Place each device squarely on top of the one below, in any order. Installing an Optional Module into the Switch E xp an 1000 BASE SX-S C Ex si on M od ul e pans ion Mo dule VM251 2A-1SX-SC -M TX RX Figure 3-5. Installing an Optional Module Caution: DO NOT install slide-in modules with the switch powered on.
Installing the VDSL Switch and Splitter Installing a GBIC Transceiver Figure 3-6. Installing a GBIC Transceiver Caution: Install only 5 V GBIC transceivers into the module slots. You can install a GBIC transceiver as described below: 1. Insert the transceiver with the SC connector facing out toward you. Note that the transceiver is keyed so that it can only be installed in one orientation. 2.
Powering On the Switch Connecting to the Stack’s Backplane Plug one end of the provided stack cable in the “Down” port of the top unit and the other end to the “Up” port of the next unit. Repeat this step for each unit in the stack. Form a simple chain starting at the “Down” port on the top unit and ending at the “Up” port on the bottom unit (stacking up to 8 units).The VDSL Switch-VS2512A supports a wrap-around stacking feature.
Installing the VDSL Switch and Splitter 3. Check the front-panel LEDs as the switch is powered on to be sure the Power LED is lit. If not, check that the power cable is correctly plugged in. The switch will automatically select the setting that matches the connected input voltage. Therefore, no additional adjustments are necessary when connecting it to any input voltage within the range marked on the front panel. 4. The switch performs a self-diagnostic test upon power-on.
Chapter 4: Making Network Connections Twisted-Pair Devices Each device requires an unshielded twisted-pair (UTP) cable with RJ-45 connectors at both ends. For 100BASE-TX connections, Category 5 cable is required; for 10BASE-T, Category 3, 4 or 5 cable can be used. Cabling Guidelines The RJ-45 ports on the switch support automatic MDI/MDI-X operation, so you can use standard straight-through twisted-pair cables to connect to any other network device (PCs, servers, switches, routers, or hubs).
Making Network Connections .
Connecting to the Punch-down Blocks 2. Label the cables to simplify future troubleshooting.
Making Network Connections Caution: This switch uses lasers to transmit signals over fiber optic cable. The lasers are compliant with the requirements of a Class 1 Laser Product and are inherently eye safe in normal operation. However, you should never look directly at a transmit port when it is powered on. 1. Remove and keep the SC port’s rubber cover. When not connected to a fiber cable, the rubber cover should be replaced to protect the optics. 2. Check that the fiber terminators are clean.
Appendix A: Troubleshooting Diagnosing Switch Indicators The VDSL Switch-VS2512A can be easily monitored through panel indicators to identify problems.The table below describes common problems you may encounter and possible solutions. If the solutions in the table fail to resolve the problem contact Accton Technical Support for advice. Symptom POWER indicator does not light up after power on. Cause Power outlet, power cord, or internal power supply may be defective.
Troubleshooting Installation Verify that all system components have been properly installed. If one or more components appear to be malfunctioning (such as the power cord or network cabling), test them in an alternate environment where you are sure that all the other components are functioning properly. In-Band Access You can access the management agent in the switch from anywhere within the attached network using Telnet, a Web browser, or other network management software such as AccView.
Appendix B: Cables Specifications. Cable Types and Specifications Cable Type Max. Length Connector 10BASE-T Cat. 3, 4, 5 100-ohm UTP 100 m (328 ft) RJ-45 100BASE-TX Cat. 5 100-ohm UTP 100 m (328 ft) RJ-45 1000BASE-SX 50/125 or 62.5/125 micron core MMF See the following table SC or ST 1000BASE-LX 9/125 micron SMF 5 km (3.12 miles) SC or ST 1000BASE-LH 9/125 micron SMF 70 km (43.5 miles) SC or ST 100BASE-FX 50/125 or 62.5/125 micron multimode fiber 2 km (1.
Cables 10BASE-T/100BASE-TX Pin Assignments For 100BASE-TX/10BASE-T connections, a twisted-pair cable must have two pairs of wires. Each wire pair is identified by two different colors. For example, one wire might be red and the other, red with white stripes. Also, an RJ-45 connector must be attached to both ends of the cable. With 100BASE-TX/10BASE-T cable, pins 1 and 2 are used for transmitting data, and pins 3 and 6 for receiving data.
Twisted-Pair Cable and Pin Assignments 1000BASE-T Pin Assignments 1000BASE-T ports switch support automatic MDI/MDI-X operation, so you can use straight-through cables for all network connections to PCs or servers, or to other switches or hubs. The table below shows the 1000BASE-T MDI and MDI-X port pinouts. These ports require that all four pairs of wires be connected. Note that for 1000BASE-T operation, all four pairs of wires are used for both transmit and receive.
Cables Adjusting Existing Category 5 Cabling to Run 1000BASE-T If your existing Category 5 installation does not meet one of the test parameters for 1000BASE-T, there are basically three measures that can be applied to try and correct the problem: 1. Replace any Category 5 patch cables with high-performance Category 5e cables. 2. Reduce the number of connectors used in the link. 3. Reconnect some of the connectors in the link.
Console Port Pin Assignments Console Port Pin Assignments The DB-9 serial port on the switch’s front panel is used to connect to the switch for out-of-band console configuration. The on-board menu-driven configuration program can be accessed from a terminal or a PC running a terminal emulation program. The pin assignments used to connect to the serial port are provided in the following tables. Figure 2-1.
Cables B-6
Appendix C: Specifications VDSL Switch Model VDSL Switch-VS2512A Physical Characteristics VDSL Specificationss Supports evolving ETSI, ANSI and ITU standards Modulation: 4 to 256 QAM Frequency Division Duplexing Data Rate: Up to 15 Mbps symmetric Range: Up to 1525 m (5000 ft) Ports 1 RJ-21 Port (contains 12 VDSL lines) 1 Stacking Port Pair 1 Slide-in Module Slot Interfaces VDSL Line: RJ-21 flat cable Stacking Ports: IEEE 1394 FireWire connectors Buffer Architecture 16 Mbytes Switch Fabric Bandwidth 9.
Specifications Humidity Operating: 5% to 90% AC Input 100 to 240 V, 50 to 60 Hz Power Consumption 40 Watts maximum Heat Dissipation 137 BTU/hr maximum Maximum Current 0.5 A @ 110 VAC 0.25 A @ 240 VAC Switch Features Spanning Tree Protocol Forwarding Mode Store-and-forward Throughput Layer 2: wire speed Flow Control Full Duplex: IEEE 802.3x Half Duplex: Back pressure Broadcast Storm Suppression Traffic throttled above a critical threshold VLAN Support Up to 255 groups; port-based or with 802.
VDSL Switch Management Features In-Band Management Telnet, Web-based HTTP, or SNMP manager (AccView Network Management software provided free) Out-of-Band Management RS-232 DB-9 console port Software Loading TFTP in-band or XModem out-of-band MIB Support MIB-II (RFC1213), Interfaces Evolution MIB (RFC 2863), Ethernet-Like MIB (RFC 2665), Bridge MIB (RFC 1493), Extended Bridge MIB: P-bridge, Q-bridge (RFC2674), RMON MIB (RFC 2819), Entity MIB (RFC 2737), RADIUS authentication client MIB (RFC 2618), Accton’s
Specifications Immunity EN 61000-4-2/3/4/5/6/8/11 Safety CSA/NRTL (CSA 22.2.950 & UL 1950) EN 60950 (TÜV/GS) CB (UEC60950) Warranty Limited Lifetime VDSL Splitter Models VM2524 VM2548 Ports VM2524: 1 RJ-21 Port (contains 24 VDSL lines) VM2548: 2 RJ-21 Ports (each port contains 24 VDSL lines) Network Interface RJ-21 flat cable Weight 3 kg (6 lbs 10 oz) Size 44.0 x 35.2 x 4.4 cm (17.4 x 13.9 x 1.7 in.
Slide-in Modules Immunity EN 61000-4-2/3/4/5/6/8/11 Safety CSA/NRTL (CSA 22.2.950 & UL 1950) EN60950 (TÜV/GS) CB (UEC60950) Warranty Limited Lifetime Slide-in Modules 1000BASE-SX Extender Module Model VM2512A-SX-SC-M Ports 1 1000BASE-SX SC-type port Network Interface SC connector, 50/125 or 62.5/125 micron multimode fiber cable Operating Mode Fixed at 1000 Mbps, full duplex Auto-negotiation of flow control Standards IEEE 802.
Specifications 1000BASE-T Extender Module Model VM2512A-1GT Ports 1 1000BASE-T RJ-45 port Network Interface RJ-45 connector, 100-ohm Category 5 or 5e twisted-pair cable (using all four wire pairs) Operating Mode 1 Gbps, full duplex, autonegotiation of speed and flow control 10/100 Mbps, full and half duplex, autonegotiation of speed, duplex mode, and flow control Standards IEEE 802.
Slide-in Modules 10/100BASE-TX Extender Modules Models VS2512A-4TX VS2512A-1TX Ports VS2512A-4TX 4 10/100BASE-T RJ-45 ports VS2512A-1TX 1 10/100BASE-T RJ-45 port Network Interface RJ-45 connector, 100-ohm , UTP cable 10BASE-T - Categories 3, 4, or 5 100BASE-TX - Category 5 Operating Mode 10/100 Mbps, full and half duplex Auto-negotiation of speed and flow control Standards IEEE 802.3 IEEE 802.3u IEEE 802.
Specifications C-8
Slide-in Modules C-9
Specifications C-10
Appendix D: Ordering Information VDSL Switch-VS2512A Products and Accessories Product Number Description VS2512A 12-port VDSL switch with one media expansion slot VS2524 24-port VDSL switch with one media expansion slot and one SFP slot VM2524 24-port VDSL Splitter VM2548 48-port VDSL Splitter ES2002-TS VDSL CPE VS2524-1SX-SC-M Gigabit module with one 1000BASE-SX multimode fiber port (SC connector) VS2524-1LX-SC-S Gigabit module with one 1000BASE-LX single-mode fiber port (SC connector) VS25
Ordering Information D-2
Glossary 10BASE-T IEEE 802.3 specification for 10 Mbps Ethernet over two pairs of Category 3, 4, or 5 UTP cable. 100BASE-FX IEEE 802.3u specification for 100 Mbps Fast Ethernet over two strands of 50/125 or 62.5/125 micron core fiber cable. 100BASE-TX IEEE 802.3u specification for 100 Mbps Fast Ethernet over two pairs of Category 5 UTP cable. 1000BASE-LX IEEE 802.3z specification for Gigabit Ethernet over two strands of 50/125, 62.5/125 or 9/125 micron core fiber cable.
Glossary Collision Domain Single CSMA/CD LAN segment. Customer Premises Equipment (CPE) Terminating equipment, such as terminals, phones, routers and routers, supplied by the phone company, installed at customer sites, and connected to the phone company network. CSMA/CD CSMA/CD (Carrier Sense Multiple Access/Collision Detect) is the communication method employed by Ethernet, Fast Ethernet, or Gigabit Ethernet. End Station A workstation, server, or other device that does not forward traffic.
Glossary IEEE 802.3ab Defines CSMA/CD access method and physical layer specifications for 1000BASE-T Fast Ethernet. IEEE 802.3u Defines CSMA/CD access method and physical layer specifications for 100BASE-TX Fast Ethernet. IEEE 802.3x Defines Ethernet frame start/stop requests and timers used for flow control on full-duplex links. IEEE 802.3z Defines CSMA/CD access method and physical layer specifications for 1000BASE Gigabit Ethernet. LAN Segment Separate LAN or collision domain.
Glossary Private Branch Exchange (PBX) A telephone exchange local to a particular organisation who use, rather than provide, telephone services. POTS Plain Old Telephone Service. Redundant Power Unit (RPU) A backup power supply that automatically takes over in case the primary power supply should fail. RJ-45 Connector A connector for twisted-pair wiring. Splitter A filter to separate DSL signals from POTS signals to prevent mutual interference.
Index Numerics 1000BASE-LX connections 4-3 1000BASE-SX connections 4-3 1000BASE-X connections 4-3 100BASE-FX connections 4-3 100BASE-LH connections 4-3 100BASE-LX connections 4-3 A accessories, ordering D-1 adhesive feet, attaching 3-4 applications Internet connections 2-2 VLAN connections 2-3 B brackets, attaching 3-3 broadcast storm control 1-3 buffer size C-1 C cable specifications B-1 cleaning fiber terminators 4-4 compliances EMC C-3, C-4 safety C-4, C-5 console port 1-3 pin assignments B-5 contents
Index IGMP Snooping 1-3 multimode and single-mode fiber optic cables 4-3 multimode fiber optic cables 4-3 N network connections 4-1, 4-3 null-modem cable 1-3 O optional modules, installation 3-3 ordering information D-1 out-of-band management 1-3 P package contents 3-2 pin assignment RJ21 B-4 pin assignments B-1 1000BASE-T B-3 10BASE-T/100BASE-TX B-2 console port B-5 DB-9 B-5 port saturation 1-3 port-based VLANs 2-3 ports, connecting to 4-1, 4-3 power, connecting to 3-7 priority queues 1-4 problems, trou
Index Web-based management 1-3 Weighted Round Robin Queuing 1-4 Index-3
Index Index-4
VS2412A VM2524, VM2548 E072002-R01 150000010100A