Fast SwitcHub-2se &INO
Installation Manual Fast SwitcHub-2se Smart Fast Ethernet Switch with 1 10BASE-T/100BASE-TX Port and 1 100BASE-FX Port
Copyright (c) 1996 by Accton Technology Corporation. All rights reserved. No part of this document may be copied or reproduced in any form or by any means without the prior written consent of Accton Technology Corporation. Accton makes no warranties with respect to this documentation and disclaims any implied warranties of merchantability, quality, or fitness for any particular purpose. The information in this document is subject to change without notice.
Package Contents Carefully unpack the contents of the package and verify them against the checklist given below. Package Checklist æ Fast SwitcHub-2se (Model No. ES3002-TF) æ AC power cord æ Four rubber foot pads æ Installation manual æ Owner registration card Please inform your dealer immediately should there be any wrong, missing or damaged parts. If possible, retain the carton, including the original packing materials. Use them again to repack the unit in case there is a need to return it for repair.
Quick Installation The Fast SwitcHub-2se contains 2 Ethernet ports that can operate at full duplex or half duplex. One of these ports supports 100BASE-TX or 10BASE-T (twistedpair) connection, while the other port supports 100BASE-FX (fiber optic) connection. The smart design built into the front display panel and configure options, provides a friendly interface that simplifies installation and network troubleshooting.
Fast SwitcHub-2se User’s Guide 5. Set the transmission mode for each port to full or half duplex. Full-duplex communications can only be supported for a dedicated link (i.e., set the communications to half duplex if you are connecting to a shared collision domain). Transmission must be set to full duplex or half duplex depending on the mode supported by the connected device. You must manually set the required mode with the Configure button (Chapter 2). 6.
About this Guide This guide is designed for the experienced network installer. It describes how to install and operate Accton’s Fast SwitcHub-2se Ethernet switch. After reading this manual, you should be able to use the front display panel and configure options to manage all your network connections.
Contents Chapter 1: Introduction........................................................... 1-1 Switching Technology...............................................................................................1-1 Accton’s Smart Extender...........................................................................................1-2 Switching Methods....................................................................................................1-3 Features of the Fast SwitcHub-2se ........................
Fast SwitcHub-2se User’s Guide Chapter 3: Hardware Reference............................................. 3-1 Front Panel ...............................................................................................................3-1 Configure Button ..................................................................................................3-2 SmartWatch Indicator Panel .................................................................................3-3 Power .....................................
Fast SwitcHub-2se User’s Guide Appendix D: Regulatory Standards Compliance.................. D-1 EMI Warning ............................................................................................................D-1 FCC Class B Certification ....................................................................................D-1 Voluntary Control Council for Interference (VCCI-2) .........................................D-3 EN55022 Declaration of Conformance ............................................
Chapter 1: Introduction Switching Technology The Ethernet Switch allows simultaneous transmission of multiple packets via an internal high-speed data channel. This means that it can partition a network more efficiently than bridges or routers. The Ethernet Switch is therefore fast being recognized as one of the most important building blocks for today’s networking technology.
Fast SwitcHub-2se User’s Guide Accton’s Smart Extender Accton’s Fast SwitcHub-2se can boost network bandwidth fourfold (i.e., if running at 100 Mbps and using full-duplex operation for both ports). It provides one 10/100 Mbps RJ-45 port for 10BASE-T or 100BASE-TX media attachment (which is automatically detected by the switch), and one 100 Mbps fiber optic port for 100BASE-FX media attachment via an SC or ST type connector.
Fast SwitcHub-2se User’s Guide speed 100BASE-TX or conventional 10BASE-T networks to the newer generation of 100BASE-FX devices; or can be used to significantly extend a 100BASE-TX or 10BASE-T network with an intermediate fiber optic link (i.e., by chaining two or more switches). Moreover, by breaking your network into smaller and more manageable segments, each linked to the larger network with a switch, the maximum distance for communications between end-nodes is unlimited.
Fast SwitcHub-2se User’s Guide dynamically changes the way it handles data passing through the switch based on the current error rate. These switching alternatives start at standard cutthrough for a clean data environment, change to fragment-free cut-through for a moderate error rate, and then progress to store-and-forward for a highly contentious environment. By using this method, the Fast SwitcHub-2se delivers the best networking performance under any environment.
Fast SwitcHub-2se User’s Guide • Uses “on the fly” cut-through technique to transport packets • Transparent bridging function supported • Address learning function to build the routing information database • Operates at maximum packet filtering and forwarding rate • Supports multimode fiber optic backbone of up to 2 kilometers for a dedicated link (i.e., a full-duplex connection) or 180 meters for a shared collision domain (i.e.
Chapter 2: Setup and Configuration This chapter provides information on pre-installation requirements, establishing network connections, and configuring the system. Pre-Installation Requirements Before you start making network connections to the SwitcHub, make sure you can provide the right operating environment, including power requirements, and proximity to other network devices that are to be connected. Verify the following installation requirements: • Power requirements: 100 to 240 VAC at 50 to 60 Hz.
Fast SwitcHub-2se User’s Guide Making RJ-45 Connections 1. Prepare a straight-through twisted-pair cable with RJ-45 plugs at both ends. 2. If you are making a connection to a server or workstation (i.e., a dedicated connection to an end-node device), be sure that it has a properly installed 100BASE-TX or 10BASE-T network interface card. Attach one end of the cable to the MDI-X station port on the switch and the other end to the RJ-45 port of the device’s network interface card.
Fast SwitcHub-2se User’s Guide Making Fiber Optic Connections 1. Prepare a pair of fiber optic cables with SC or ST type connectors at both ends. SC-Type Connector ST-Type Connector 2. If you are making a connection to a server or workstation, be sure that it has a properly installed 100BASE-FX network interface card. Connect the Rx/Tx jacks on the target device to the Tx/Rx jacks on the switch. - When using fiber optic cabling, the maximum length between two switches can be up to 2 kilometers.
Fast SwitcHub-2se User’s Guide For a sample calculation, assume the following values: • cable gauge - 62.5/125 mm, which means a 13 dB power budget, • 2 patch panels between the switches, each with 0.5 dB power loss, and 1 splice with 0.4 dB power loss (i.e., 2 * 0.5 + 0.4 = 1.4 dB power loss for intervening devices), and • inherent power loss in the cable is 4.5 dB/km The maximum cable length is therefore: m ≤ 13 dB - 1.4 dB ≤ 2.58 km 4.
Fast SwitcHub-2se User’s Guide Providing Power to the SwitcHub 1. Power on the switch by plugging the power cord into the power socket at the rear of the SwitcHub, and the other end into a power outlet. 2. Check the LED marked Power on the front panel to see if it is on. The unit will automatically select the setting that matches the connected input voltage. Therefore, no additional adjustments are necessary when connecting it to any input voltage within the range marked on the rear panel. 3.
Fast SwitcHub-2se User’s Guide Setting the Display Mode The Configure button is located on the left front panel. This button is used to access the following configuration functions in sequence: • Bandwidth Utilization • Forwarding Ratio • Filtering Ratio • Collision Ratio • Full/Half Duplex • Diagnostics The percentage of LAN bandwidth utilized. The percentage of packets that are forwarded to the other port. The percentage of packets filtered because the destination is in the current segment.
Fast SwitcHub-2se User’s Guide Selections Available This section shows the information available for each display mode and the corresponding LED indicators. The display functions are listed here in the sequence selected by the Configure button. For a more detailed description of these indicators, refer to Chapter 3. Bandwidth Utilization Active LED: Util% (ON) In this mode, the statistical indicators show the percentage of valid data handled by each port on the switch compared to available bandwidth.
Fast SwitcHub-2se User’s Guide Full/Half Duplex Mode Selection Active LED: Full/Half (ON) This function is used to set the communication mode for selected ports to full duplex or half duplex. 1. Use the Configure button to light the Full/Half Display Mode indicator. Note that before the Configure button is released, the current communication mode selections will be displayed by the Port Status Full LEDs (i.e.
Fast SwitcHub-2se User’s Guide Verifying Port Status Check each connection by viewing the port status indicators listed below. (For a more detailed description of these indicators, refer to Chapter 3.) • Link Indicates that the port has established a valid network connection. • Transmit Indicates outgoing traffic traversing the port. • Receive Indicates incoming traffic entering the port. • Full Indicates that communications have been set to full-duplex mode.
Fast SwitcHub-2se User’s Guide • When making a fiber optic connection, be sure the Tx/Rx ports on the switch are attached to the Rx/Tx ports on the other device. Verify that the fiber optic cable snaps into place when attached. • Be sure the length of fiber optic cable does not exceed 2 kilometers for a dedicated link or 180 meters when used in a shared collision domain. (Be sure to consider signal attenuation when determining the maximum length of fiber optic cable.
Chapter 3: Hardware Reference The Fast SwitcHub-2se is a highly reliable network switch that complies with IEEE 802.3 (10BASE-T) and IEEE 802.3u (100BASE-TX and 100BASE-FX) specifications. This switch delivers superior performance compared to the bridge and router solution, and at a much lower cost. By confining local traffic to the originating segment, and only forwarding cross-segment traffic to the other port, this switch meets the requirements for Ethernet and IEEE 802.3 networks.
Fast SwitcHub-2se User’s Guide Configure Button The Configure button is located on the left front panel.
Fast SwitcHub-2se User’s Guide SmartWatch Indicator Panel The comprehensive LED array on the front panel (1) shows if the unit is receiving power, (2) indicates the current display mode, (3) displays network performance for each port, (4) indicates the status of port connections, and (5) shows the result of diagnostic tests. The following figure shows the LED indicators, each of which are described in the following sections. Power Display Mode Performance Indicators Figure 3.
Fast SwitcHub-2se User’s Guide Statistical Display for System Performance (Utilization, Forward, Filter & Collision Display Mode) Display Mode Port 1 Port 2 Statistical Indicators Value Color: Green and Orange Active LEDs: LED rows labeled 1 and 2 (which indicate the status of Port 1 and Port 2 respectively Function: Indicates a functional value for each port depending on the selected display mode.
Fast SwitcHub-2se User’s Guide For example, if network utilization reaches 1%, the LED labeled 1% will light up. However, if network utilization rises above 35%, the LED labeled 35 and all the other LEDs before it (i.e., 1, 5, 10 and 20) will also light up in rapid succession. These indicators monitor the share of valid network frames handled by each port within a 10 Mbps or 100 Mbps bandwidth, depending on the Ethernet type currently plugged into the back panel.
Fast SwitcHub-2se User’s Guide collisions encountered by the corresponding port. When collisions reach a level marked on the front panel display, the corresponding LED lights up. For example, if packet collision reaches 1%, the LED labeled 1% will light up. However, if collisions go beyond 30%, the LED labeled 30+% and all the other LEDs before it (i.e., 1, 5, 10 and 20) also light up in rapid succession.
Fast SwitcHub-2se User’s Guide Diagnostics Display Mode Color: Active LED: Function: Green Diag Indicates that the system is in Diagnostic mode. (Refer to the Configure Button section earlier in this chapter for instructions on how to select the display mode.) After power on, the switch automatically performs a self-diagnostic test. This test is done in two stages. The first stage is the System Diagnostic Test, and the second stage is the Port Diagnostic Test.
Fast SwitcHub-2se User’s Guide Port Diagnostic Test The Port Diagnostic Test checks all ports. If a problem is detected, an LED in the corresponding row (which indicates the malfunctioning port) and column (which indicates the failed component) will light up as shown below.
Fast SwitcHub-2se User’s Guide Transmit (TX) - Indicates outgoing traffic traversing the port. LED Activity BLINKING LIGHT Condition ON NO LIGHT OFF Receive (RX) - Indicates Indication Indicates the port is transmitting packets; blinking is proportional to the traffic passing through the port. No packets are being transmitted from this port. incoming traffic entering the port.
Fast SwitcHub-2se User’s Guide Rear Panel The unit’s rear panel includes two Ethernet ports and a full-range power socket. Although 10 Mbps and 100 Mbps connections are automatically sensed by the SwitcHub, you must use the Configure button to set the data transfer mode to full-duplex or half-duplex operation, as described under Setting the Communication Mode in this chapter. The following figure shows the rear panel. Figure 3.
Fast SwitcHub-2se User’s Guide Notes: 1. Both 50/125 mm and 62.5/125 mm cable are commonly available. 2. This same guage of mutilmode fiber optic cable can be used for making connections to both 10 Mbps and 100 Mbps Ethernet. Therefore, when upgrading older fiber optic Ethernet to the newer Fast Ethernet, check to see if you actually need to change your present cabling. Power Socket The power socket accepts AC power from 100 to 240V at 50 to 60Hz.
Appendix A: Troubleshooting Diagnosing Switch Indicators The Fast SwitcHub-2se can be easily monitored through its comprehensive panel indicators. These indicators assist the network manager in identifying problems the switch may encounter. This section describes common problems you may encounter and possible solutions. Symptom: Link indicator does not light up (green LED) after making a connection. Cause: Workstation’s network adapter, cable or switch port is defective.
Fast SwitcHub-2se User’s Guide System Diagnostics Installation Verify that all system components have been properly installed. If one or more components appear to be malfunctioning, test them in an alternate environment where you are sure that all the other components are functioning properly. Transmission Mode Be sure each port on the SwitcHub is set to the same transmission mode as the attached device; i.e., full duplex or half duplex.
Fast SwitcHub-2se User’s Guide Configuration If problems occur after altering the network configuration, restore the original connections, then try to track the problem down by implementing the new changes, one step at a time. Ensure that cable distances and other physical aspects of the installation do not exceed recommendations. Switch Integrity As a last resort verify the switch’s integrity with a power-on reset. Turn the power to the switch off and then on.
Appendix B: Port and Cable Assignments RJ-45 Port Figure B-1 RJ-45 Connector (on the Switch Side) Pin 1 2 3 6 4,5,7,8 MDI-X Assignment Station Port 1 Input Receive Data + Input Receive Data Output Transmit Data + Output Transmit Data Not Used MDI Assignment Cascade Port 1 Output Transmit Data + Output Transmit Data Input Receive Data + Input Receive Data Not Used Table B-1 RJ-45 Pin Assignments Schematics for both straight and crossover twisted-pair cable are shown below.
Appendix C: Specifications Product Specifications Basic Criteria Access Method Standards Conformance Communication Mode Media Supported Dimensions Input Power Power Consumption Temperature Humidity Certification Emissions Immunity Safety CSMA/CD, 10/100 Mbps (auto-sensed) IEEE 802.3 10BASE-T, IEEE 802.3u 100BASE-TX and 100BASE-FX Full duplex or half duplex 10BASE-T Category 3,4,5 twisted-pair cable (100W) 100BASE-TX Category 5 twisted-pair cable (100W) 100BASE-FX 50/125 mm or 62.
Appendix D: Regulatory Standards Compliance EMI Warning FCC Class B Certification Accton Technology Corporation Model Numbers: ES3002-TF FCC ID: HED3002ESLCT-TF This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation.
Fast SwitcHub-2se User’s Guide You are cautioned that changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment. Warnings 1. Wear an anti-static wrist strap or take other suitable measures to prevent electrostatic discharge whenever handling this equipment. 2. When connecting this device to a power outlet, connect the field ground lead on the tri-pole power plug to a valid earth ground line to prevent electrical hazards.
Fast SwitcHub-2se User’s Guide Voluntary Control Council for Interference (VCCI-2) This equipment is in the 2nd Class category and conforms to the standards set by the Voluntary Control Council for Interference by Data Processing Equipment and Electronic Office Machines aimed at preventing radio interference in residential areas. 2nd Class category equipment is qualified to be used in or near residential areas.
Fast SwitcHub-2se User’s Guide EN55022 Declaration of Conformance This is to certify that this product is shielded against the generation of radio interference in accordance with the application of Council Directive 89/336/EEC, Article 4a. Conformity is declared by the application of EN55022:1987 Class B (CISPR 22:1985/BS 6527:1988). CE Mark Declaration of Conformance This is to certify that this product complies with ISO/IEC Guide 22 and EN45014.
Fast SwitcHub-2se User’s Guide Safety Compliance Underwriters Laboratories Compliance Statement Important! Before making connections, make sure you have the correct Cord Set. Check it (read the label on the cable) against the following specification list.
Fast SwitcHub-2se User’s Guide Sicherheitshinweise 1. Die Steckdose muß sich in der Nähe des Gerätes befinden und leicht zugänglich sein. 2. Zum Reinigen den Stecker aus der Steckdose ziehen. Beim Reinigen keine Flüssigreiniger oder Sprays verwenden, sondern ein angefeuchtetes Tuch. 3. Das produkt gerät nicht in Naßräume oder in der Nähe von Wasser benutzen, wie z.B. Badezimmer, Schwimmbad, Spülbecken usw. . Das Eindringen von Wasser kann zur Zerstörung des Gerätes führen. 4.
Appendix E: Product Support Services Product Registration Fill in the Owner Registration Card and mail it to Accton Technology Corporation. Accton will keep your record and inform you of any new Accton unit developments. Problem Report If problems occur during unit operation, please check the adapter configuration settings, cables, connectors, network terminators, hardware compatibility and other network components.
Fast SwitcHub-2se User’s Guide After repair, Accton will inform you of the date of delivery and the exact amount due. Please send the payment by T/T (Telegram Transfer), and Accton will send you the fixed component after receiving payment. With or without warranty, if the hardware is found to be free of defects, you will only be charged for testing and handling. Software Update and Upgrade Service Accton constantly improves its software units by adding enhancements and new features.
Fast SwitcHub-2se User’s Guide Technical Support Your dealer or installer is the person who understands your network and Accton units. If neither is available to help you, Accton technical support engineers are available by FAX, mail or phone. • Send your technical questions by FAX to: International Headquarters: 886-3-5770-267 USA Headquarters: 408-452-8988 • To obtain software upgrades connect via ftp to ftp.accton.com.tw • Send your technical questions by email to support@accton.com.
Fast SwitcHub-2se User’s Guide Limited Warranty Accton warrants to the original owner that the product delivered in this package will be free from defects in material and workmanship for the lifetime of the product. For the warranty to apply, you must register your purchase by returning the registration card indicating the date of purchase and including proof of purchase. There will be a minimal charge to replace consumable components, such as fuses, power transformers, and mechanical cooling devices.
Fast SwitcHub-2se User’s Guide Return Process Before you may return any Accton product to Accton, you must request an RMA number by calling, FAXing or writing Accton’s Service Department at the address listed below. If you ship the product, you must assume the risk of damage or loss in transit. You must use the original container (or the equivalent) and pay the shipping charge.
Fast SwitcHub-2se User’s Guide Accton Offices Accton Technology Corporation International Headquarters, No. 1 Creation Rd. III, Science-based Industrial Park, Hsinchu 300, Taiwan, R.O.C.
Glossary 10BASE-T IEEE’s specifications for 10 Mbps Ethernet using twisted-pair cable (100W STP or UTP). The maximum length of cable for a point-to-point connection is 100 meters. 100BASE-TX IEEE’s specifications for 100 Mbps Ethernet using twisted-pair cable (100W STP or UTP). The maximum length of cable for a point-to-point connection is 100 meters. 100BASE-FX IEEE’s specifications for 100 Mbps Ethernet using multimode fiber optic cable.
Fast SwitcHub-2se User’s Guide Daisy-Chain Port MDI port on the SwitcHub. Port 1 can be used to connect the Fast Ethernet switch to other compatible switches or other network interconnection devices. Ethernet A network communication system developed and standardized by DEC, Intel, and Xerox, using baseband transmission, CSMA/CD access and logical bus topology, and coaxial cable. The successor IEEE 802.
Fast SwitcHub-2se User’s Guide MDI-X Port (Medium Dependent Interface - Crossed) This RJ-45 port, which crosses the receive and transmit signals internally, can be used with straight-through cable to connect the switch to any workstation or server that has a properly installed network adapter card. Pin-out assignments are shown in Appendix B. RJ-45 Connector Most common terminator for twisted-pair wiring.
Index C I Configure Button • 3-2 Connecting the Switch System • 2-1 Connections Fiber Optic • 2-3 RJ-45 • 2-2 Verifying • 2-9 Crossover Cable • B-1 Cut-through Switching • 1-2 Installation Requirements • 2-1 D Diagnostic Tests • 2-5 Display Mode • 2-5 Distance Limit in Fiber Optics • 2-3 E EMI Warning • D-1 Ethernet Ports • 3-10 F L LED Indicators 100 • 3-9 Coll% • 3-5 Diag • 3-7 Filter% • 3-5 Forward% • 3-5 Full • 3-9 Full/Half • 3-6 Link • 3-8 Power • 3-3 RX • 3-9 Statistical Display • 3-4 TX • 3-9
Fast SwitcHub-2se User’s Guide Port Status Indicators • 3-8 Ports 100BASE-FX • 3-10 100BASE-TX or 10BASE-T • 3-10 Power Loss in Fiber Optics • 2-3 Power Socket • 3-11 Product Features • 1-4 Product Specifications • C-1 Product Support Services • E-1 Accton Offices • E-6 Bulletin Board Service • E-2 Hardware Repair Service • E-1 Interactive Fast Fax • E-2 Ordering Information • E-6 Software Update and Upgrade Service • E-2 Technical Support • E-3 Providing Power to the SwitcHub • 2-4 R Rear Panel • 3-10 RJ-